PROGRAM DESCRIPTION
Current (A) Voltage (V)
Desulphation Soft start Bulk Absorption
Revives a
sulphated battery
Tests the state
of the battery
Main charge
Top charge and
minimaluidloss
YES 4A for max 8h until the
voltage reaches 12.6V.
4A for max 20h. A combination of
current limits and
timers, max 10h.
YES 0.8A for max 8h until
the voltage reaches
12.6V.
0.8A for max 20h. A combination of
current limits and
timers, max 10h.