AIB Hardware Reference Option Switches
CTI Products, Inc.
68-10842-115
7
Clock and RX Clock) are used for direct connection between the AIB and
ASTRO-TACâ„¢ Comparator.
TX Clock Source
SER MODE
position 1
OPTION B
position 3
Internal (default) DOWN UP
External UP DOWN
Table 4 - Transmit Clock Selection
RX Clock Source
SER MODE
position 2
OPTION B
position 4
Internal (default) DOWN UP
External UP DOWN
Table 5 - Receive Clock Selection