Manual
CTI Products, Inc. HIB-IP & HIB-IP 8000 Hardware Reference Manual
2. IP Address Configuration 11
IP SETTINGS WORKSHEET
Gather the following IP information for the system. IP information must be obtained for each HIB-IP module
to be used (from the network administrator responsible for the IP network to which the HIB-IP module will be
attached):
Individual HIB-IP Parameters:
For each HIB-IP in the system, gather the following information:
HIB-IP Number
Name
HIB-IP Address (Host IP Address)
_____._____._____._____
Subnet Mask
_____._____._____._____ or ____ Use Global
Gateway IP Address
_____._____._____._____
MCN Group (00-FE)
MCN Module Number (00-7F)
Note: the Subnet Mask cannot be less restrictive than the following standard IP Class Subnet Masks
Class First Octet Standard Subnet Size Standard Subnet Mask
A 1-127 16,777,214 255.0.0.0
B 128-191 65,543 255.255.0.0
C 192-223 253 255.255.255.0
D 224-239 Multicast – Do not use.
E 240-255 Experimental – Do not use.
The HIB-IP units can accept a subnet mask that is more restrictive (more 1's set in the Subnet Mask), but not
less restrictive.
The Gateway address is the address of the router used to communicate with PCs in other subnets. The Gateway
subnet must be the same as the HIB-IP unit's subnet. If it is set to Empty, the HIB-IP will not be able to
communicate to PCs outside of its subnet.
Authorized PCs:
For each PC in the system that will connect to the HIB-IP, collect the following information:
PC Name
PC IP Address (Host IP Address)
_____._____._____._____
See the MCN series Software manual for instructions on:
• Entering this data into the configuration files using MCN Config series of software
• Downloading the configuration data into the HIB-IP units.
The configuration is downloaded from the PC to the HIB-IP unit using an 89-11314 Null-Modem serial cable
(9-pin female to 9-pin female.).