Owner manual

Interfacing to IP Comparators MLC 8000 Comparator
54 68-12286-110
MLC Tech Display Table
The MLC Tech Display Table is provided to help technicians troubleshoot MLC 8000 Analog
Comparator systems. Separate screens or tabs can be set up using this Display Table for Technician use.
The MLC Tech Display Table adds the more technical indication to the display including Signal Quality
and TX indication. The possible states for the MLC 8000 Analog Comparator subsites (receivers) using
this Display Table are:
Displayed State
Meaning
Error
Undefined Status
Offline
Server cannot communicate with MLC 8000 Analog Comparator
(Note 1)
Config Err
(Note 2)
(Blank)
No Activity
Disable
Disabled via MCN Server 8000 or MCN Client
Fail
Subsite Failed - Comparator cannot communicate to BR (Note 3)
Rx
Receive Signal Quality 0
| Rx
Receive Signal Quality 1
|| Rx
Receive Signal Quality 2
||| Rx
Receive Signal Quality 3
|||| Rx
Receive Signal Quality 4
||||| Rx
Receive Signal Quality 5
TX
Transmit Active
Tx/Rx
Tx & Rx Signal Quality 0
| Tx/Rx
Tx & Rx Signal Quality 1
|| Tx/Rx
Tx & Rx Signal Quality 2
||| Tx/Rx
Tx & Rx Signal Quality 3
|||| Tx/Rx
Tx & Rx Signal Quality 4
||||| Tx/Rx
Tx & Rx Signal Quality 5
Vote
Vote Signal Quality 0
| Vote
Vote Signal Quality 1
|| Vote
Vote Signal Quality 2
||| Vote
Vote Signal Quality 3
|||| Vote
Vote Signal Quality 4
||||| Vote
Vote Signal Quality 5
Last Vote
Last subsite voted (LV Display Tables only)
The above states are defined in the MLC Tech Display Table only.
Notes 1-4: Same as for previous table.
Note 5: This table is best used with a fixed width font (such as Courier New) so that the signal bars
align.
Note 6: Do not use this Display Table for normal users. It will be too cluttered.
WARNING: DO NOT ATTEMPT TO CHANGE THE BIT VALUES OR ENTRY ORDER IN
THE DISPLAY TABLE.