PC DISPLAY
The MCN PC can display the status of a number of points in the OTAL system:
Signal From the following module
Local PTT (1-8) OTAL CIB in the OTAL Driver Assembly
Remote PTT (1-8) Remote PTT CIB (if used)
COR Signals (1-8) Remote COR CIB
OTAL Signal (1-8) OTAL CIB in the OTAL Driver Assembly
Keyup Fail (1-8) OTAL CIB in the OTAL Driver Assembly
OTAL Power Status (1-2) OTAL CIB in the OTAL Driver Assembly
IIB Link Status (1-2) OTAL CIB in the OTAL Driver Assembly
MCN CONFIG RESOURCES
Use the following resources in the MCN Config program to configure an OTAL system in the MCN system:
Module Device in MCN Config
PTT CIB CIB (8 PTT signals)
COR CIB CIB (8 COR signals)
OTAL CIB CIB OTAL Alarm
(8 OTAL sections – OTAL & Keyup Fail))
The OTAL CIB Alarm device has the following 12 Function Blocks (Receivers):
• (8) OTAL & Keyup Fail
• IIB Link 1 (from Remote PTT CIB)
• IIB Link 2 (from Remote COR CIB)
• OTAL PS A (typically AC Power)
• OTAL PS B (typically DC Power)
Function Block Display Table
Remote PTT PTT
COR COR
OTAL & Keyup Fail CIB OTAL Alarm
(Displays Local PTT, OTAL & Keyup Fail)
OTAL PS OK-Fail
IIB Link OK-Fail