User Manual

TSAM Installation and Maintenance Rev. 2.10 Chapter 4
CTI Products, Inc. Installation
31
4.11 Secondary Frequency Tone Table
The following table shows the relationship between the secondary frequency inputs, the secondary channel
frequencies, and the base station frequencies.
TSAM P201 Pin 38 12 37 11
Base Function
Secondary Freq /SF8 /SF4 /SF2 /SF1 Freq Tone (Hz)
Note 1 X X X X F1 1950
1 H H H H F2 1850
2 H H H L F3 1350
3 H H L H F4 1250
4 H H L L F5 1750
5 H L H H F6 1650
6 H L H L F7 1550
7 H L L H F8 1450
8 H L L L F9 950
9 L H H H F10 850
10 L H H L F11 650
11 L H L H F12 spare
12 L H L L F13 spare
13 L L H H F14 spare
14 L L H L F15 spare
15 L L L H F16 spare
Not Used L L L L None None
Table 6 Frequency Select Tone Table
Note 1: The Main channel uses F1 in the base station. Secondary Frequency Select signals start at F2 and
have no effect on the Main Channel keying tones.
Note 2: The frequencies shown above are the default function tone frequencies. They will vary if the
frequencies are changed from the programming port.
Note 3: Default programming supports SF inputs for Secondary Frequencies 1-10.
Note 4: Inputs are active low. L < 2.0 V, H > 10 V.