Use and Care Manual

5
32 590 11 Rev. D
KohlerEngines.com
EN
High Altitude Operation
This engine may require a high altitude carburetor kit to ensure correct engine operation at
altitudes above 4000 ft. (1219 meters). To obtain high altitude kit information or to nd a Kohler
authorized dealer visit KohlerEngines.com or call 1-800-544-2444 (U.S. and Canada).
This engine should be operated in its original con guration below 4000 ft. (1219 meters) as
damage may occur if high altitude carburetor kit is installed and operated below 4000 ft. (1219
meters).
Maintenance Instructions
WARNING
Before working on engine or equipment, disable
engine as follows: 1) Disconnect spark plug
lead(s). 2) Disconnect negative (–) battery cable
from battery.
Accidental Starts can cause
severe injury or death.
Disconnect and ground spark
plug lead(s) before servicing.
Normal maintenance, replacement or repair of emission control devices and systems may be
performed by any repair establishment or individual; however, warranty repairs must be performed
by a Kohler authorized dealer found at KohlerEngines.com or 1-800-544-2444 (U.S. and Canada).
Oil Recommendations
We recommend use of Kohler oils for best
performance. Other high-quality detergent
oils (including synthetic) of API (American
Petroleum Institute) service class SJ or higher
are acceptable. Select viscosity based on air
temperature at time of operation as shown in
table below.
°F
-20
020324060
50 80 100
°C
-30 -20
-10 0
10 20 30
40
5W-30
10W-30
SAE 30
Check Oil Level
NOTE: To prevent extensive engine wear or
damage, never run engine with oil level
below or above operating range
indicator on dipstick.
Ensure engine is cool. Clean oil ll/dipstick
areas of any debris.
1. Remove dipstick; wipe oil off.
2. Reinsert dipstick into tube; press completely
down.
3. Remove dipstick; check oil level. Level
should be at top of indicator on dipstick.
4. If oil is low on indicator, add oil up to top of
indicator mark.
5. Reinstall and secure dipstick.
Maintenance Schedule
Every 25 Hours¹
Service/replace precleaner.
Replace air cleaner element (if not equipped with precleaner).
Every 100 Hours¹
Replace air cleaner element (if equipped with precleaner).
Change oil and lter.
Remove cooling shrouds and clean cooling areas.
Every 100 Hours
Check that all fasteners are in place and components are properly secured.
Replace fuel lter.
Every 500 Hours²
Have valve lash checked/adjusted.
Every 500 Hours
Replace spark plugs and set gap.
¹ Perform these procedures more frequently under severe, dusty, dirty conditions.
² Have a Kohler authorized dealer perform this service.