MSDS

Page 1
Form #: MSDS 853024
Revised: 06/06/2013
Supersedes: 05/01/2011
ECO #: 1001294
I. PRODUCT IDENTIFICATION
Chemical Trade Name (as used on label): Chemical Family/Classification:
Electric Storage Battery
Manufacturer's Name/Address: Telephone:
EnerSys For information and emergencies, contact EnerSys'
P.O. Box 14145 Environmental, Health & Safety Dept. at 610-208-1996
2366 Bernville Road 24-Hour Emergency Response Contact:
Reading, PA 19612-4145
CHEMTREC INTERNATIONAL: 703-527-3877
II. HAZARDOUS INGREDIENTS/IDENTIFY INFORMATION
CAS Number
Approximate % by
Wt. Or Vol.
OSHA ACGIH NIOSH
Inorganic Lead Compound:
Lead 7439-92-1 45 - 60 50 150 100
* Lead Dioxide 1309-60-0 15 - 25 50 150 100
* Antimony 7440-36-0 2 500 500 --
* Arsenic 7440-38-2 0.2 10 200 --
* Calcium 7440-70-2 0.2 -- -- --
* Tin 7440-31-5 0.2 2000 2000 --
Electrolyte (Sulfuric Acid) 7664-93-9 10-30 1000 1000 1000
Case Material: 5-10 N/A N/A N/A
Polypropylene 9003-07-0
Polystyrene 9003-53-6
Styrene Acrylonitrile 9003-54-7
Acrylonitrile Butadiene Styrene 9003-56-9
Styrene Butadiene
9003-55-8
Polyvinylchloride 9002-86-2
Polycarbonate, Hard Rubber, Polyethylene --
Other:
Silicon Dioxide (Gel batteries only) 7631-86-9 20-40 N/A N/A N/A
Sheet Molding Compound -- N/A N/A N/A
(Glass reinforced polyester)
Inorganic lead and electrolyte (sulfuric acid) are the primary components of every battery manufactured by EnerSys.
Other ingredients may be present dependent upon battery type. Contact your EnerSys representative for additional information.
III. PHYSICAL DATA
Electrolyte:
Boiling Point: 203 - 240° F Specific Gravity (H2O = 1): 1.215 to 1.350
Melting Point: N/A Vapor Pressure (mm Hg): 10
Solubility in Water: 100% Vapor Density (AIR = 1): Greater than 1
Evaporation Rate: (Butyl Acetate = 1) Less than 1 % Volatile by Weight: N/A
Appearance and Odor:
IV. FIRE AND EXPLOSION HAZARD DATA
Flash Point: N/A Flammable Limits: LEL = 4.1% (Hydrogen Gas) UEL = 74.2%
Extinguishing Media: CO2; foam; dry chemical
Special Fire Fighting Procedures:
If batteries are on charge, shut off power. Use positive pressure, self-contained breathing apparatus. Water applied to electrolyte generates
heat and causes it to spatter. Wear acid-resistant clothing.
Unusual Fire and Explosion Hazards:
Highly flammable hydrogen gas is generated during charging and operation of batteries. To avoid risk of fire or explosion, keep sparks or other
sources of ignition away from batteries. Do not allow metallic materials to simultaneously contact negative and positive terminals of cells and
batteries. Follow manufacturer's instructions for installation and service.
V. REACTIVITY DATA
Stability: Stable
Conditions To Avoid: Prolonged overcharge; sources of ignition
Incompatibility: (Materials to avoid)
Sulfuric Acid: Contact with combustibles and organic materials may cause fire and explosion. Also reacts violently with strong reducing agents,
metals, sulfur trioxide gas, strong oxidizers and water. Contact with metals may produce toxic sulfur dioxide fumes and may release flammable
hydrogen gas.
Lead Compounds: Avoid contact with strong acids, bases, halides, halogenates, potassium nitrate, permanganate, peroxides, nascent hydrogen
and reducing agents.
MATERIAL SAFETY DATA SHEET
Nonspillable Lead-Acid Battery
CHEMTREC DOMESTIC: 800-424-9300
Manufactured article; no apparent odor. Electrolyte is a clear liquid with a sharp, penetrating, pungent odor.
Air Exposure Limits (ug/m
3
)
Components

Summary of content (4 pages)