  No information available. 
  (f) Interactions with Other Chemicals 
 No information available. 
3.  Composition/information on ingredients 
(a) Mixtures information 
Chemical name 
CAS No. 
Concentration% 
Lithium Cobalt Oxide(CoLiO2) 
12190-79-3 
29.23 
Graphite 
7782-42-5 
22.87 
Copper 
7440-50-8 
8.51 
Aluminum foil 
7429-90-5 
15.16 
Phosphate(1-), hexafluoro-, lithium 
21324-40-3 
3.44 
Carbon black 
1333-86-4 
1.00 
Polypropylene 
9003-07-0 
4.13 
Polyethylene 
9002-88-4 
3.58 
Nickel(Ni) 
7440-02-0 
6.08 
O-Ny 
24937-16-4 
6 
4.  First-aid measures 
(a) Description of first aid measures 
          General Advice            First aid is upon rupture of sealed battery. 
Eye contact: 
Show this safety data sheet to the doctor in attendance. 
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Keep 
eye  wide  open  while  rinsing.  Remove  contact  lenses,  if  present  and  easy  to  do.  Continue 
rinsing. Get medical attention if irritation develops and persists. Do not rub affected area. 
Skin contact: 
Remove  contaminated  clothes and  rinse the  skin  with  plenty  of water.  Get  medical  advice / 
attention if you feel unwell. 
Inhalation: 
Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, (trained 
personnel should) give oxygen. Get medical advice / attention if you feel unwell. 
Ingestion: 
Rinse  mouth  immediately  and  drink  plenty  of  water.  Never  give  anything  by  mouth  to  an 
unconscious person. Do NOT induce vomiting. Get medical aid. 
Self-protection of 
the first aider 
Ensure  that  medical  personnel  are  aware  of  the  material(s)  involved,  take  precautions  to 
protect themselves and prevent spread of contamination. 
(b) Most important symptoms/effects, acute and delayed 
Contact  with  internal components may cause  allergic skin  sensitization  (rash)  and irritate  eyes,  skin,  nose,  throat, 
respiratory system. Cobalt and Cobalt compounds are considered to be possible human carcinogen(s).   
(c) Immediate medical attention and special treatment 
No information available. 