Specifications
Frequency Range 2 to 30 MHz
Power Output 5,000 watts PEP and average (±0.5dB)
with VSWR less than or equal to 1.3:1
Power Input < 100mW PEP/average for rated power output
Input Impedance 50 ohm, 1.5:1 VSWR maximum
Gain Variation 1.5dB maximum over frequency range
VSWR Turndown Operates at reduced power from 1.3:1 to 3:1 VSWR
Stable at any load; protected for infinite VSWR
3rd Order IMD >32 dB below PEP
RF Noise At least 75 dBc/Hz below a 5 kW
output reference level
Spurious Emissions -60 dBc or better within ±5% of the
operating frequency. At least -80
dBc beyond ±5% from the operating frequency.
Harmonic Levels -63 dBc or better at rated power into a 50 ohm load
Frequency Change 20 ms maximum between any two frequencies
Time
Key Control RF Power is within ±1 dB of steady
state level in less than 10 ms after key
ON. RF power is reduced by more than
50 dB within 5 ms after key OFF
Altitude Operating: 0 to 10,000 ft
Nonoperating: 0 to 50,000 ft
Temperature Operating: 0°C to + 40°C at sea level;
maximum temperature derated linearly to
+ 20°C at 10,000 ft
Nonoperating: -40°C to + 70°C
Humidity 0 to 95% relative humidity, non-condensing
Cooling Forced air-internal fans.
Acoustic Noise 73 dBa
Power Supply Built in
AC Line Input 3 phase, 47 to 63 Hz
187-240 VAC at 50A maximum per phase
or 373-457 VAC at 25A maximum per phase
Indicator LEDs System Controller
Power Amplifier Modules
Power Supply
Control RS-232/422/485 serial bus
BIT parameters via serial bus
Dimensions 85.5” (217cm) (H) x 31.6” (80.3cm) (D) x 23.7”
(60.2cm) (W)
Weight <800lb (< 363kg)
9333 Balboa Ave. • San Diego, California • USA • Phone 858-277-6780 • Fax 858-505-1523
Copyright 09/15 • CDA 11738_168