User's Manual

351804-1 Rev. 100
COM5000-8 TECHNICAL MANUAL
31
CHAPTER 5
MAINTENANCE
5.1 INTRODUCTION
The maintenance chapter contains a list of recommended test equipment, and instructions for mechanical
disassembly, for verifying the performance of the amplifier, for routine adjustments, and for aligning the
Transmitter.
For maintenance refer to the Transmitter Interconnect Wiring diagram 351803, figure 5.1.
5.2 RECOMMENDED TEST EQUIPMENT
Equipment Manufacturer
RF Signal Generator Agilent model N5171B
Wattmeter Bird model 4421
10 kW sensor Bird model 4024
1 kW sensor Bird model 4021
50 ohm Load, 10kW Bird model 8931-230*
Directional Coupler, 10kW Werlatone model C1449
50 ohm Load/Attenuator, 4kW Bird model 8329-300 with BA-230*
20dB Attenuator, 1W Mini-Circuits model HAT-20
Variable Step Attenuator JFW model 50BR-017
Spectrum Analyzer Agilent model N9320B
Oscilloscope Tektronix model TDS2012C
DVM Fluke model 77
*Uses 230VAC blowers. For 115VAC, change -230 to -115 in model number.
Note: Equivalent equipment may be substituted.
5.3 PERIODIC MAINTENANCE
The only items that require regular maintenance are the air filters. The filters should be removed and
cleaned periodically at a frequency determined by the operating environment. The filters are located on the
front panel of the modules.
To remove the filters simply pull out the filter from the bracket.
The filter can be washed with a diluted soap solution. Dry the filter completely before replacement.
5.4 MODULE AND SUBASSEMBLY MAINTENANCE
All factory supplied spare modules and subassemblies are aligned prior to shipment and adjustments are
normally not required following replacement of a particular subassembly obtained from the factory. The
following maintenance procedures are intended for use if minor repairs have been performed in the field or
for other reasons the equipment requires alignment.