REVISION DATE DOCUMENT NAME DOCUMENT NUMBER PAGE
E.00 06 Apr 05
Installation Guide for the Small GO CARD Access Control Target
061-9214 4
Table 1. ACT Terminal Block Wiring Connections (Configuration 1)
Terminal Function Comment
1 Internal 5 volts Provides +5 volts at up to 100 mA
2 External 5 volts Isolator and LED power (Requires +5 volts at 20 mA)
3 Data 1 Optically isolated data out
4 Data 0 Optically isolated data out
5 LED High = Red, low = Green, unconnected = Yellow
6 External Common Isolator and LED power and data signal common
7 Power Common Unit power and internal +5 volt common
8 Unit Power Requires from +8 to +28 volts at up to 2.5 watts
2.2 WIRING FOR CONFIGURATION 2
Connections are as shown in Table 2 along with the following considerations:
1. Power is supplied on pins 7 and 8.
2. If the ACT is used with an existing access controller, pins 2 through 6 of the ACT are connected to the
access controller standard five-wire interface.
3. If the controller used does not require optical isolation and does not provide 5 volt power, connect pin 2
to pin 8 and pin 6 to pin 7. This uses the reader’s external power for the optical isolator and the LED,
but defeats the optical isolation by connecting the signal and power grounds.
4. If the ACT is programmed (via an activation card) to output Wiegand data, the data output appears on
pins 3 and 4. If the unit is programmed to output serial or magnetic-stripe data, the data appears only
on pin 3.
Table 2. ACT Terminal Block Wiring Connections (Configuration 2)
Terminal Function Comment
1 Test For production use
2 External 5 to 28 volts Isolator and LED power (Requires 5 to 28 Vdc at 20 mA)
3 Data 1 Optically isolated data out
4 Data 0 Optically isolated data out
5 LED High = Red, low = Green, unconnected = Yellow
6 External Common Isolator and LED power and data signal common
7 Power Common Unit power and internal +5 volt common
8 Unit Power Requires from +8 to +28 volts at up to 2.5 watts
This document contains proprietary and confidential information originated or owned by Cubic Transportation Systems, Inc. (Cubic). Neither this document nor the information disclosed
herein shall be reproduced or transferred to other documents or used or disclosed to others for manufacturing or any other purposes except as specifically authorized in writing by Cubic.