Specifications

Table Of Contents
Product Catalog, January 2012
www.cuesystem.com
M F
• Power relay unit up to 10 A per channel for resistive loads
• Eight independent potential free switching outputs
• Eight inputs for external switches (wall buttons, etc.)
• Controlled by serial channel RS-485
• Test buttons on front panel
• Indication of power and serial channel activity
• Indication of power relay status
• Unified enclosure designed for DIN rail installation
• Easy installation
Control ports
8x Digital contact closure input, 2x 8-pin connetor
Power ports
4x Potential free relay C-NO, up to 230 V
Max. 10 A for resistive loads
Max. 400 W per relay for inductive or capacitive loads
4x Potential free relay NC-C-NO, 230 V
Max. 10 A for resistive loads
Max. 400 W per relay for inductive or capacitive loads
Terminals 1.5 mm2
LED indicators
Power, serial channel activity, all power ports
Buttons
8x Test button for power relay control
1x ACT button for address and bank settings
Insulation strength
2.5 kV between power and control circuits
Serial communication
RS-485, 5-pin connector
Insulation strength
2.5 kV between power and control circuits
Power supply
110 or 230 VAC, 50 / 60 Hz, 6 W
Terminals 1.5 mm2
Physical
Plastic DIN rail compatible enclosure
Dimensions
159 x 90 x 58 mm / 6.2” x 3.5” x 2.3”
9 DIN modules 17.5 mm
Weight 0.5 kg / 1.1 lb
Operating environment
Temperature 0° to 60° C
Humidity 10% to 90% non-condensing
S D
The relayCUE-8 is an eight-channel relay switching unit for loads up to
10 A per channel. The unit can be controlled by serial channel RS-485
and by potential free contact inputs. These contact inputs are intended to
be used mainly as “wall switches” for direct control of dedicated relay
circuits. To fulfil various tasks, the input operation can be assigned to
different functions by setting their functional parameters in the project
configuration. The programmable parameters are response on the input,
delayed on / off, pulse, and drapes and motor control sequence. Basic
parameters can be set using buttons on front panel, other parameters
are set by serial channel. Front panel includes LED indicators for power
supply, serial channel activity and status of all power relays. The unit can
be combined with all Power Express units. The enclosure allows simple
installation on a DIN rail.
S B C
relayCUE-8
Connector set
Cable RS-485 5-pin to RJ-11
PEbus cable adapter
Warranty Conditions, CE Declaration, RoHS Declaration
Data Sheet, Cue System Connector Wiring Sheet
CUE Application CD
O I
Product codes
CS0335-1 version 110 VAC
CS0335-2 version 230 VAC
relayCUE-8
A
• Complete residential automation
• High-tech homes
• Commercial single-room applications
• Meeting rooms, conference rooms, boardrooms
• Huge multi-room and multi-floor distributed systems
A N
The relay contacts are constructed for resistive load up to
230 V / 10 A. If these relays are used for the switching of inductive or
capacitive loads, voltage or power peaks can occur, which may exceed
these parameters even if the load has the stated take-off lower than
230 V / 10 A. We therefore do not recommend using relayCUE-8 for
switching inductive or capacitive loads with take-off higher than 400 W.
If you need to switch higher inductive or capacitive loads, use contactors.
Unlike relays, contactors are designed with features to control and
suppress the arc produced when interrupting inductive load currents. You
can then use the relay of the unit to control the coil of this contactor.