For more information, please visit the product page. date 11/07/2014 page 1 of 30 SERIES: NQB-N │ DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS GENERAL CHARACTERISTICS FEATURES • • • • • • • pin and function compatible with Architects of Modern Power™ product standards • industry standard quarter-brick 57.9 x 36.8 x 11.3 mm (2.28 x 1.45 x 0.445 in) • industry-leading power density for telecom and datacom 127~141W / sq. in • high efficiency, typ. 96.
For more information, please visit the product page.
For more information, please visit the product page. CUI Inc │ SERIES: NQB-N │ DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS date 11/07/2014 │ page 3 of 30 General Information Reliability The failure rate (λ) and mean time between failures (MTBF= 1/ λ) is calculated at max output power and an operating ambient temperature (TA) of +40°C. CUI Power Modules uses Telcordia SR-332 Issue 2 Method 1 to calculate the mean steady-state failure rate and standard deviation (σ).
For more information, please visit the product page. CUI Inc │ SERIES: NQB-N │ DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS date 11/07/2014 │ page 4 of 30 Absolute Maximum Ratings parameter conditions/description min operating temperature (TP1) see thermal consideration section typ max units -40 +125 °C storage temperature (TS) -55 +125 °C input voltage (VI) -0.
For more information, please visit the product page. CUI Inc │ SERIES: NQB-N │ DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS date 11/07/2014 │ page 5 of 30 Electrical Specification 12.0 V, 35 A, 420 W TP1, TP3 = -40 to +90ºC, VI = 36 to 75 V. Typical values given at: TP1, TP3 = +25°C, VI = 53 V, max IO, unless otherwise specified under Conditions. Additional Cout = 3.
For more information, please visit the product page. CUI Inc │ SERIES: NQB-N │ DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS date 11/07/2014 │ page 6 of 30 Typical Characteristics 12.0 V, 35 A / 420 W Efficiency Power Dissipation [W] 24 [%] 100 20 95 53 V 53 V 8 75 V 80 48 V 12 48 V 85 36 V 16 36 V 90 75 V 4 75 0 0 5 10 15 20 25 30 0 35 [A] 5 10 15 20 25 30 35 [A] Dissipated power vs. load current and input voltage at TP1, TP3 = +25°C Efficiency vs.
For more information, please visit the product page. CUI Inc │ SERIES: NQB-N │ DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS date 11/07/2014 │ page 7 of 30 Typical Characteristics 12.0 V, 35 A / 420 W Start-up Start-up enabled by connecting VI at: TP1, TP3 = +25°C, VI = 53 V, IO = 35 A resistive load. Shut-down Top trace: output voltage (5 V/div.). Bottom trace: input voltage (50 V/div.). Time scale: (10 ms/div.).
For more information, please visit the product page. CUI Inc │ SERIES: NQB-N │ DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS date 11/07/2014 │ page 8 of 30 Typical Characteristics 12.0 V, 35 A / 420 W Output Current Derating – Open frame [A] 35 3.0 m/s 30 2.0 m/s 25 1.5 m/s 20 15 1.0 m/s 10 0.5 m/s 5 Na t. Co nv. 0 0 20 40 60 80 100 [°C] Available load current vs. ambient air temperature and airflow at VI = 53 V. See Thermal Consideration section.
For more information, please visit the product page. CUI Inc │ SERIES: NQB-N │ DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS date 11/07/2014 │ page 9 of 30 Electrical Specification 12.0 V, 39 A / 468 W TP1, TP3 = -40 to +90ºC, VI = 40 to 60 V. Typical values given at: TP1, TP3 = +25°C, VI = 53 V, max IO, unless otherwise specified under Conditions. Additional Cout = 3.
For more information, please visit the product page. CUI Inc │ SERIES: NQB-N │ DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS date 11/07/2014 │ page 10 of 30 Typical Characteristics 12.0 V, 39 A / 468 W Efficiency Power Dissipation [%] [W] 25 100 20 95 40 V 90 48 V 60 V 80 48 V 53 V 10 53 V 85 40 V 15 60 V 5 0 75 0 5 10 15 20 25 30 35 40 [A] 0 5 10 15 20 25 30 35 40 [A] Dissipated power vs. load current and input voltage at TP1, TP3 = +25°C Efficiency vs.
For more information, please visit the product page. CUI Inc │ SERIES: NQB-N │ DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS date 11/07/2014 │ page 11 of 30 Typical Characteristics 12.0 V, 39 A / 468 W Start-up Start-up enabled by connecting VI at: TP1, TP3 = +25°C, VI = 53 V, IO = 39 A resistive load. Shut-down Top trace: output voltage (5 V/div.). Bottom trace: input voltage (50 V/div.). Time scale: (10 ms/div.).
For more information, please visit the product page. CUI Inc │ SERIES: NQB-N │ DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS date 11/07/2014 │ page 12 of 30 Typical Characteristics 12.0 V, 39 A / 468 W Output Current Derating – Open frame [A] 40 35 3.0 m/s 30 2.0 m/s 25 1.5 m/s 20 1.0 m/s 15 0.5 m/s 10 Na t. Con v. 5 0 0 20 40 60 80 100 [°C] Available load current vs. ambient air temperature and airflow at VI = 53 V. See Thermal Consideration section.
For more information, please visit the product page. CUI Inc │ SERIES: NQB-N │ DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS date 11/07/2014 │ page 13 of 30 Electrical Specification 12.45 V, 35 A / 415 W TP1, TP3 = -40 to +90ºC, VI = 36 to 75 V. Typical values given at: TP1, TP3 = +25°C, VI = 53 V, max IO, unless otherwise specified under Conditions. Additional Cout = 3.
For more information, please visit the product page. CUI Inc │ SERIES: NQB-N │ DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS date 11/07/2014 │ page 14 of 30 Typical Characteristics 12.45 V, 63 A / 747 W, two products in parallel Efficiency Power Dissipation [W] 45 [%] 100 40 35 95 36 V 90 48 V 53 V 85 75 V 80 30 36 V 25 48 V 20 53 V 15 75 V 10 5 75 0 0 10 20 30 40 50 60 0 [A] 10 20 30 40 50 60 [A] Dissipated power vs.
For more information, please visit the product page. CUI Inc │ SERIES: NQB-N │ DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS date 11/07/2014 │ page 15 of 30 Typical Characteristics 12.45 V, 35 A / 415 W Output Current Derating – Open frame [A] 35 3.0 m/s 30 2.0 m/s 25 1.5 m/s 20 15 1.0 m/s 10 0.5 m/s 5 Na t. Co nv. 0 0 20 40 60 80 100 [°C] Available load current vs. ambient air temperature and airflow at VI = 53 V. See Thermal Consideration section.
For more information, please visit the product page. CUI Inc │ SERIES: NQB-N │ DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS date 11/07/2014 │ page 16 of 30 Electrical Specification 12.45 V, 39 A / 462 W TP1, TP3 = -40 to +90ºC, VI = 40 to 60 V. Typical values given at: TP1, TP3 = +25°C, VI = 53 V, max IO, unless otherwise specified under Conditions. Additional Cout = 3.
For more information, please visit the product page. CUI Inc │ SERIES: NQB-N │ DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS date 11/07/2014 │ page 17 of 30 Typical Characteristics 12.45 V, 70 A / 830 W, two products in parallel Efficiency Power Dissipation [%] [W] 45 100 40 35 95 40 V 90 48 V 53 V 85 60 V 80 30 40 V 25 48 V 20 53 V 15 60 V 10 5 75 0 0 10 20 30 40 50 60 0 70 [A] 10 20 30 40 50 60 70 [A] Dissipated power vs.
For more information, please visit the product page. CUI Inc │ SERIES: NQB-N │ DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS date 11/07/2014 │ page 18 of 30 Typical Characteristics 12.45 V, 39 A / 462 W Output Current Derating – Open frame [A] 40 35 3.0 m/s 30 2.0 m/s 25 1.5 m/s 20 1.0 m/s 15 0.5 m/s 10 Na t. Con v. 5 0 0 20 40 60 80 100 [°C] Available load current vs. ambient air temperature and airflow at VI = 53 V. See Thermal Consideration section.
For more information, please visit the product page. CUI Inc │ SERIES: NQB-N │ DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS date 11/07/2014 │ page 19 of 30 EMC Specification Conducted EMI measured according to EN55022, CISPR 22 and FCC part 15J (see test set-up). The fundamental switching frequency is 140 kHz for NQB at VI = 53 V, max IO.
For more information, please visit the product page. CUI Inc │ SERIES: NQB-N │ DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS The input voltage range 40 to 60 Vdc meets the requirements for normal input voltage range in -48 V systems, -40.5 to -57.0 V. At input voltages exceeding 60 V, the power loss will be higher than at normal input voltage and TP1 must be limited to absolute max +125°C. The absolute maximum continuous input voltage is 65 Vdc.
For more information, please visit the product page. CUI Inc │ SERIES: NQB-N │ DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS automatically when the temperature has dropped below the temperature threshold; the hysteresis is defined in general electrical specification. The product has also an under temperature protection. Over Voltage Protection (OVP) The product includes over voltage limiting circuitry for protection of the load. The OVP limit is 30% above the nominal output voltage.
For more information, please visit the product page. CUI Inc │ SERIES: NQB-N │ DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS Definition of product operating temperature The product operating temperature is used to monitor the temperature of the product, and proper thermal conditions can be verified by measuring the temperature at positions P1, P2, P3 and P4. The temperature at these positions (TP1, TP2, TP3, TP4) should not exceed the maximum temperatures in the table below.
For more information, please visit the product page. CUI Inc │ SERIES: NQB-N │ DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS date 11/07/2014 │ page 23 of 30 Mechanical Information - Hole Mount, Open Frame Version Top View Pin Positions According To Recommended Footprint Table 1. X1 = Ordering information PIN SPECIFICATIONS Pin 1, 2, 4, 5 & 16 Material: Copper alloy Plating: Min Au 0.1 µm over 1-3 µm Ni.
For more information, please visit the product page. CUI Inc │ SERIES: NQB-N │ DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS date 11/07/2014 │ page 24 of 30 Mechanical Information - Hole Mount, Base Plate Version Top View Pin Positions According To Recommended Footprint Table 1. X1 = Ordering information CASE Material: Aluminum For screw attachment apply mounting torque of max 0.44 Nm [3.9 lbf in]. M3 screws must not protrude more than 2.7mm [0.106] into the base plate.
For more information, please visit the product page. CUI Inc │ SERIES: NQB-N │ DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS date 11/07/2014 │ page 25 of 30 Mechanical Information - Surface Mount Version Top View Pin Positions According To Recommended Footprint Recommended Footprint - Top View PIN SPECIFICATIONS Pin 1, 2, 4, 5 & 16 Material: Copper alloy Plating: Min Au 0.1 µm over 1-3 µm Ni. Weight: Typical 46 g All dimensions: mm [inch] Tolerances: x.x ±0.50 [0.02] x.xx ±0.25 [0.
For more information, please visit the product page. CUI Inc │ SERIES: NQB-N │ DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS date 11/07/2014 │ page 26 of 30 Soldering Information - Surface Mounting Lead-free (Pb-free) solder processes The surface mount product is intended for forced convection or vapor phase reflow soldering in SnPb and Pb-free processes.
For more information, please visit the product page. CUI Inc │ SERIES: NQB-N │ DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS date 11/07/2014 │ page 27 of 30 Soldering Information - Hole Mounting The hole mounted product is intended for plated through hole mounting by wave or manual soldering. The pin temperature is specified to maximum to 270°C for maximum 10 seconds. A maximum preheat rate of 4°C/s and maximum preheat temperature of 150°C is suggested.
For more information, please visit the product page. CUI Inc │ SERIES: NQB-N │ DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS Tray Specifications - TH Material PE Foam Surface 105 < Ohm/square < 1012 resistance Bakability The trays are not bakeable Tray capacity 20 converters/tray Box capacity 20 products (1 full tray/box) Product – Open frame 1100 g full tray, 140g empty tray Weight Product – Base plate option 1480 g full tray, 140 g empty tray cui.
For more information, please visit the product page.
For more information, please visit the product page. CUI Inc │ SERIES: NQB-N │ DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS date 11/07/2014 │ page 30 of 30 REVISION HISTORY rev. date 1.01 11/07/2014 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com Novum and Architects of Modern Power are trademarks of CUI.