Datasheet
cui.com
CUI Inc │ SERIES: PQM1-M │ DESCRIPTION: DC-DC CONVERTER date 04/08/2014 │ page 5 of 6
1. Output load requirement
To ensure this module can operate effi ciently and reliably, the minimum output load may not be less than 10% of the full load during
operation. If the actual output power is low, connect a resistor at the output end in parallel to increase the load.
2. Overload Protection
Under normal operating conditions, the output circuit of this product has no protection against overload. The simplest method to add
this is to add a circuit breaker to the circuit.
3. Recommended circuit
If you want to further decrease the input/output ripple, you can increase the capacitance accordingly or choose capacitors with low
ESR (see Figure 2 & Table 2). However, the capacitance of the output fi lter capacitor must be appropriate. If the capacitance is too
high, a startup problem might arise. For every channel of the output, to ensure safe and reliable operation, the maximum capacitance
must be less than the maximum capacitive load (see Table 3).
APPLICATION NOTES
Note: 1. Operation under minimum load will not damage the converter; however, they may not meet all specifi cations listed.
2. Max. capacitive load tested at input voltage range and full load.
3. All specifi cations measured at: Ta=25°C, humidity<75%, nominal input voltage and rated output load, unless otherwise specifi ed.
Vout
(Vdc)
Max. Capacitive Load
(F)
3.3 220
5 220
9 220
12 220
15 220
Figure 2
Table 2
Vin
(Vdc)
Cin
(F)
Vo
(Vdc)
Cout
(F)
5 4.7 3.3 10
12 2.2 5 10
24 1 9 4.7
-- -- 12 2.2
-- -- 15 1
Note: It’s not recommended to connect any external capacitors in
applications with less than 0.5 watt output.
Table 3
Vin
GND
+Vo
0V
DC
Cin
DC
Cout
For more information, please visit the product page.