Instructions / Assembly

Model SY-2650
Substance US EPA Avg. Influent Avg. (Max) Avg. (Min)
Standard 42 MCL Concentration Effluent Conc. Reduction
Chlorine-Class I —** 2.0 mg/L 0.05 mg/L 97.5%
Particulates (0.5– —** 10,790,000 #/ml 450,000 #/ml 96.0%
<1m)-Class I
Standard 53
MTBE 0.015 mg/L .0014mg/L 90%
(.0047mg/L) (69%)
Cysts† 99.95% 572,664 #/ml 168 #/ml 99.97%
Reduction (339 #/ml) (99.96%)
Turbidity 0.5 NTU* 26 NTU 0.16 NTU 99.4%
(0.23 NTU) (99.2%)
Lead (6.5 pH) 0.010 mg/L‡ 0.15 mg/L 0.0015 mg/L 99.0%
(0.008 mg/L) (95.0%)
Lead (8.5 pH) 0.010 mg/L‡ 0.16 mg/L 0.001 mg/L 99.4%
(0.003 mg/L) (98.1%)
Mercury (6.5 pH) 0.002 mg/L 0.0058 mg/L 0.0005 mg/L 91.4%
(0.0005 mg/L) (91%)
Mercury (8.5 pH) 0.002 mg/L 0.0062 mg/L 0.00058 mg/L 90.6%
(0.0011 mg/L) (82.2%)
Asbestos 7,000,000 F/L 27,025,000 F/L 0.225 F/L 99.9%
(0.225 F/L) (99.9%)
Flow Rate=0.6 gpm (2.27 Lpm) Capacity=500 gallons (1893 L) or 6 months
*US EPA Maximum Contaminant Level
**No maximum contaminant level
†NSF test requirement of at least 50,000 3–4 micron particles per milliliter.
The 3–4 micron particle size is a surrogate particle for Cryptosporidium and Giardia cysts.
‡US EPA Action Level for Lead
Performance Data
Important Notice: Read this performance data and compare the capabilities of this system with your actual water treatment needs. It is recommended that, before
installing a water treatment system, you have your water supply tested to determine your actual water treatment needs.
6
Organic Chemicals Included by Surrogate Testing:
Chemical US EPA Influent Chemical Maximum
MCL challenge reduction product water
mg/L (ppm) concentration
1)
percent concentration
mg/L (ppm) mg/L (ppm)
alachlor 0.002 0.050 >98 0.001
atrazine 0.003 0.100 >97 0.003
benzene 0.005 0.081 >99 0.001
carbofuran 0.04 0.190 >99 0.001
carbon tetrachloride 0.005 0.078 98 0.0018
chlorobenzene 0.100 0.077 >99 0.001
chloropicrin 0.015 99 0.0002
2,4-D 0.070 0.110 98 0.0017
dibromochloropropane (DBCP) 0.0002 0.052 >99 0.00002
o-dichlorobenzene 0.600 0.080 >99 0.001
p-dichlorobenzene 0.075 0.040 >98 0.001
1,2-dichloroethane 0.005 0.088 95
4)
0.0048
1,1-dichloroethylene 0.007 0.083 >99 0.001
cis-1,2-dichloroethylene 0.070 0.170 >99 0.0005
trans-1,2-dichloroethylene 0.100 0.086 >99 0.001
1,2-dichloropropane 0.005 0.080 >99 0.001
cis-1,3-dichloropropylene 0.079 >99 0.001
dinoseb 0.007 0.170 99 0.0002
endrin 0.002 0.053 99 0.00059
ethylbenzene 0.700 0.088 >99 0.001
ethylene dibromide (EDB) 0.00005 0.044 >99 0.00002
haloacetonitriles (HAN):
bromochloroacetonitrile 0.0022 98 0.0005
dibromoacetonitrile 0.024 98 0.0006
dichloroacetonitrile 0.0096 98 0.0002
trichloroacetonitrile 0.0015 98 0.0003
haloketones (HK)
1,1-dichloro-2-propanone 0.0072 99 0.0001
1,1,1-trichloro-2-propanone 0.0082 96 0.0003
heptachlor 0.0004 0.08 >99 0.0004
heptachlor epoxide 0.0002 0.0107 98 0.0002
hexachlorobutadiene 0.044 >98 0.001
hexachlorocyclopentadiene 0.050 0.060 >99 0.000002
lindane 0.0002 0.055 >99 0.00001
methoxychlor 0.040 0.050 >99 0.0001
pentachlorophenol 0.001 0.096 >99 0.001
simazine 0.004 0.120 >97 0.004
styrene 0.100 0.150 >99 0.0005
1,1,2,2,-tetrachloroethane 0.081 >99 0.001
tetrachloroethylene 0.005 0.081 >99 0.001
toluene 1.0 0.078 >99 0.001
2,4,5-TP (silvex) 0.050 0.270 99 0.0016
tribromoacetic acid 0.042 >98 0.001
1,2,4-trichlorobenzene 0.070 0.160 >99 0.0005
1,1,1-trichloroethane 0.200 0.084 95 0.0046
1,1,2-trichloroethane 0.005 0.150 >99 0.0005
trichloroethylene 0.005 0.180 >99 0.0010
trihalomethanes (includes):
chloroform (surrogate chemical) 0.080 0.300 95 0.015
bromoform
bromodichloromethane
chlorodibromomethane
xylenes (total) 10.0 0.070 >99 0.001
Technical Support: 1-800-645-5426, Monday-Friday, 7:30 am–5:00 pm, CST
State of California
Department of Health Services
Water Treatment Device
Certificate Number
Date Issued: May 17, 2000
Date Revised: March 9, 2001
1437
00 -
Trademark/Model Designation
Replacement Element(s)
Culligan SY-2300 D-250A
Culligan SY-2300S D-250A
Culligan SY-2650 D-250A
Cysts (protozoan)
Turbidity
Asbestos
Lead
Mercury
MTBE
VOCs
Culligan
The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section
116830 of the Health and Safety Code for the following health related contaminants:
Microbiological Contaminants and Turbidity
Inorganic/Radiological Contaminants
Organic Contaminants
Alachlor
Bromodichloromethane
1
Carbon Tetrachloride
2,4-D
o-Dichlorobenzene
1,2-Dichloroethane
cis-1,2-Dichloroethylene
Dinoseb
Ethylbenzene
Hexachlorocyclopentadiene
Methoxychlor
Styrene
1,1,2,2-Tetrachloroethane
1,1,1-Trichloroethane
m-Xylene
1
Trihalomethanes
Benzene
Carbofuran
Chloroform
1
Chlorodibromomethane
1
1,1-Dichloroethylene
cis-1,3-Dichloropropylene
Endrin
Heptachlor Epoxide
Lindane
Simazine
Tetrachloroethylene
1,2,4-Trichlorobenzene
Trichloroethylene
p-Xylene
Atrazine
Bromoform
1
Chlorobenzene
DBCP
p-Dichlorobenzene
trans-1,2-Dichloroethylene
1,2-Dichloropropane
EDB
Heptachlor
Hexachlorobutadiene
Pentachlorophenol
2,4,5-TP (Silvex)
Toluene
1,1,2-Trichloroethane
o-Xylene
500 gallonsRated Service Capacity: 0.6 gpm
Rated Service Flow:
Do not use where water is microbiologically unsafe or with water of unknown quality, except that
systems claiming cyst reduction may be used on water containing cysts.
Manufacturer: