Hi-Flo 55 Filters Operating Manual MODEL NUMBER HD-202 HD-242 HD-302 HD-362 HD-423 HD-483 HD-544 HD-604 HD-726HD-846

HI-FLO
®
CULLSORB
®
AUTOMATIC FILTERS FOR
IRON AND MANGANESE REDUCTION
SPECIFICATIONS AND OPERATING DATA
Hi-Flo 55 Hi-Flo 50
MODEL NUMBER HG-202 HG-242 HG-302 HG-362 HG-423 HG-4825 HG-5425 HG-6025 HG-723 HG-844
Service Flow @ gpm 10 15 25 35 50 65 80 100 140 190
Pressure Drop @ psi @ 3 @ 3 @ 4 @ 4 @ 4 @ 4 @ 6 @ 4 @ 5 @ 6
L/min 38 57 97 132 190 250 300 380 530 720
@ kPa @ 21 @ 21 @ 28 @ 28 @ 20 @ 28 @ 41 @ 28 @ 34 @ 41
Backwash Flow gpm 30 45 70 100 135 160 210 240 350 480
L/min 110 170 270 380 510 610 800 910 1,330 1,820
Tank Size
Diameter in 20 24 30 36 42 48 54 60 72 84
mm 510 610 760 910 1,070 1,220 1,370 1,520 1,830 2,130
Sideshell in 48 48 48 54 54 60 60 60 60 60
mm 1,220 1,220 1,220 1,370 1,370 1,520 1,520 1,520 1,520 1,520
Pipe Size
Inlet/Outlet in 2 22232.52.52.534
Media Volume ft
3
5 8 12 19 25 34 43 53 76 104
m
3
0.156 0.212 0.340 0.538 0.708 0.962 1.22 1.50 2.15 2.94
Ship Weight, Approx. lb 850 1,150 1,790 2,680 3,720 7,200 9,100 11,600 17,500 27,000
kg 385 522 812 1,220 1,690 3,300 4,100 5,300 7,900 12,000
NOTES:
1 Service flow rates are based on 5 gpm/ft
2
(19 L/m
2
/min). Actual flow rate may vary depending upon the application and the raw water.
2 Backwash flow rates are based on 12-14 gpm/ft
2
(45-53 L/m
2
/min) using 50° F (10° C) water. A different backwash rate may be required depending upon
water temperature or other water conditions.
3 Operational, maintenance and replacement requirements are essential for this product to perform as advertised. Service is available through independently
operated Culligan dealerships.