Specifications

Specifications
Culligan
®
Iron Cleer
®
Filters
1
Capacity based on 4 gpm and 10 mg/L of dissolved iron.
2
Measured from top of media bed to top of inlet fitting.
3
Max flow rates & pressure drop characteristics have not been validated by the Water Quality
Association.
The max specified flow rate at which the system will deliver treated water as validated by the Water
Quality Association is defined as service flow.
1
10” Iron Cleer 12” Iron Cleer
Control Valve
1” 5-cycle reinforced
thermoplastic
1” 5-cycle reinforced
thermoplastic
Timer Electro-mechanical Electro-mechanical
Overall Conditioner Height 67” 65”
Media Tank Dimensions (D
x H)
2 ea. 10” x 54” tanks 2 ea. 12” x 52” tanks
Filter Media Type 1.0 cu. ft. birm 1.5 cu. ft. birm
Underbedding
G-50 35 lbs. 35 lbs.
Cullsan U 25 lbs. 25 lbs.
Capacity
1
1400 gallons 2000 gallons
Freeboard
2
21” 18”
Max. Clear Water (Soluble)
Iron
10 ppm 10 ppm
Max. Hydrogen Sulfide 5.0 ppm 5.0 ppm
Minimum Alkalinity 100 ppm 100 ppm
pH 7.0 - 8.5 7.0 - 8.5
Service Flow @ Pressure Drop (Clean Bed)
Normal 5 gpm @ 9 psi 7 gpm @ 10 psi
Maximum
3
6 gpm @ 9 psi 9 gpm @ 14 psi
Operating Pressure 20-60 psi 20-60 psi
Operating Temperature 33-120° F (1-48° C) 33-120° F (1-48° C)
Electrical Requirements 120 Volts/60 Hz 120 Volts/60 Hz
Power Consumption,
Continuous/Maximum
3 watts/203 watts 3 watts/203 watts
Drain Flow, Maximum 10 gpm (5.5 gpm min. required) 10 gpm (8.0 gpm min. required)
Regeneration Time
Backwash 5 - 20 minutes 5 - 20 minutes
Fast Rinse 5 - 20 minutes 5 - 20 minutes