Specifications

Display Icons
The display is to be backlit and have the icons as shown below.
Custom LCD Display
Six standard 12-segment alpha-numeric characters, a decimal separating the first and second character, a colon separating
the second and third character positions, AM, PM, REGEN, EFFICIENCY MODE, TODAY’S, AVG DAILY, WATER USAGE,
SOFTWATER, REMAINING, %, MINS, BACKWASH, BRINE RINSE, FAST RINSE, /, REFILL, GALLONS, LITERS, FLOW RATE,
GPM, LPM Icons
A further description of each programming setting and the corresponding display is outlined below. For a display that has an icon
that is displayed solid for the 2 second time period prior to bringing up the settings, the settings menu can be reached prior to the
two second time out by pressing the “Up” or “Down” key.
Beeper Setting -
This setting is used to turn the beeper on or off for each key press
actuation. The display will show “bEEP X” where X is either “Y” or “N”. The “Y” or “N”
will be toggled with the “Up” and “Down” keys. Setting the Beep option to “N” will only
disable the beeper for key press actuation. The beeper will still be active for error and
alarm codes.
Pressing the “Program” key will save the setting and move to the next programming step.
Time of Day - This setting is used to program the current time of day. When in this step the display will first show “tod” for two
seconds.
After “tod” is displayed, “12:00 PM” will display (or the current set time if already programmed) and the minutes will flash. The
minutes are adjusted with the “Up” or “Down” key until the correct value is displayed.
Press the “Regen” key to flash the hours. Adjust with the “Up” or “Down” key until the correct time is displayed.
Pressing the “Program” key will move to the next programming step. Pressing “Regen” will move back to the minutes adjust.
Time of Regeneration - This setting is used to program the time at which a regeneration
is to occur in the delay mode, or in immediate mode with time clock backup on. The
display will first show “tor” for two seconds.
After “tor” is shown the display will then show the default of 2:00 AM (or the current
programmed time of regeneration if already set). The time can be adjusted in 30 minute
increments by pressing the “Up” or “Down” keys.
Pressing the “Program” key will save the setting and move to the next programming step.
Programming 19
%
Hours FlashingMinutes Flashing
Time Flashing