Specifications
20 Culligan
®
Iron-Cleer
®
Plus Water Filters
• Pre-Rinse Mode - This setting will only be active
if dip#9 is on. The display will show “PRE-” for
two seconds and then “Rinse” in the left most
characters of the display. When “Rinse” is shown
the right most character of the display will flash
“N” and toggle to “Y” with the use of the “Up” or
“Down” keys.
Pressing the “Program” key will save the setting and move to the next programming step.
• Pre-Rinse Time Duration -
This setting is used to set the length of time that the control
will be in the fast rinse position before returning to the Service (Home) position. The
display will show “RINS” and XX where XX is the length in minutes that the control is to
pre-rinse as well as the “Fast Rinse” icon. Adjust the XX value with the “Up” and “Down”
keys.
Pressing the “Program” key will save the setting and move to the next programming step.
• Pre-Rinse Hours - This setting will only be active if the Pre-Rinse mode is set to ‘Yes’
and a flow meter is attached to the control. The display will show “HOUR” in the left most
characters and “XX” in the right most digits where “XX” represents the hours setting from
01 - 99. The hours setting is adjusted with the “Up” and “Down” keys.
Pressing the “Program” key will save the setting and move to the next programming step.
• Pre-Rinse Time of Day -
This setting will only
be active if the Pre-Rinse mode is set to ‘Yes’
and the control is operating in time clock mode.
The Display will show “Time” for 2 seconds and
then the flashing time display as in the time of
regeneration display. The time can be adjusted
in 30 minute increments with the “Up” and “Down”
keys.
Pressing the “Program” key will save the setting and move to the next programming step.
• Cycle 1 Time (Backwash) –
This setting is used to program the backwash cycle. The
time of the cycle is kept in minutes. The display will show the “Backwash” and “MINS”
icons and the cycle time in the right most digits. Adjust the value with the “Up” or “Down”
keys.
Pressing the “Program” key will save the setting and move to the next programming step.
• Cycle 2 Time (Pause) – This setting is used to set the time in minutes for cycle 2. This
cycle is usually brine draw / slow rinse for softeners and a settling time for filters. The
display will show the “Brine Rinse” and “MINS” icons and the cycle time in the right most
digits. Adjust the value with the “Up” or “Down” keys.
Pressing the “Program” key will save the setting and move to the next programming step.
• Cycle 3 Time (Fast Rinse) – This setting is used to set the time in minutes for cycle 3.
This cycle is usually fast rinse for softeners and filters. The display will show the “Fast
Rinse” and “MINS” icons for filters with the cycle time in the right most digits. Adjust the
value with the “Up” or “Down” keys.
Pressing the “Program” key will save the setting and move to the next programming step.
Time Flashing