Specifications

22 Culligan
®
Iron-Cleer
®
Plus Water Filters
Total Capacity Set Point (Max Capacity) This setting is used to program a value
that corresponds to the maximum gallons that can be expected from a unit before
media needs to be replaced (or scheduled service check is required). This setting will
only appear if a flow meter is connected to the circuit board. The display will show the
“Regen” icon and “Maxcap” for two seconds and then display the “Regen” and “Gallons”
or “Liters” icons (depending on DIPswitch # 7 setting) and the setting numbers to adjust.
Adjust the value with the “Up” or “Down” keys.
When the capacity used equals this total capacity setting with the “Life” feature off, the
control will regenerate either immediately or at the time of regen based on the “hidden
programming menu” setting. With the “Life” feature on, the control will use this setting to
trigger the “Change Media” alarm.
Pressing the “Program” key will save the setting and move to the next programming step.
Batch Set Point This setting is used to set
the trip point for regeneration when in flow meter
operation. It will only appear if a flow meter is
connected. The programmed setting displays
the actual set point to trigger regeneration. The
display will show the “Regen” icon and “bAtCH”
for two seconds and then display the “Regen” and
“Gallons” or “Liters” icons (depending on dip #7 setting) and the setting numbers to adjust. Adjust the value with the “Up” or
“Down” keys.
Pressing the “Program” key will save the setting and move to the next programming step.
Hidden Menu
Power Outage - The power outage option can be
toggled off and on by pressing and holding “Up”
and “Down” keys simultaneously for 5 seconds.
This option sets whether a regeneration should
occour immediately or delayed after a 3 hour or
longer power outage. Also, it determines whether
an immediate regeneration occurs when Maxcap
is reached.
Pressing the “Program” key will save and go to the next hidden menu option.
Program Lock -
The program lock can be toggled
off and on by pressing the “Up” and “Down” keys.
The display will show “UNLOCK” or “LOCK”
depending on the last setting. When locked, the
only program menus that can be changed are
‘beeper’, TOD, and TOR. The other menus will
appear as normal but their values will not be able
to be changed.
Pressing the “Program” key will return to the regular time of day display in standard service mode.
OOO8 7O