Specifications

text Information Function Timeout
If no key activity occurs for a period of 600 seconds (10 minutes) while in information functions mode, the mode will time out and
return to the time of day display. An exception is that the flow rate and % capacity remaining will not time out but will remain
displayed until a key is pressed. Pressing the “Information” key after the last standard information display will return the unit back to
the time display.
Manual Control Cycling
The control can be manually cycled through a regeneration to troubleshoot the control or verify that the set-up is complete. When
a control is manually cycled back to the service position, the statistical counters of capacity remaining, days since last regeneration,
last slow rinse time and the number of regenerations in the last 14 days and the life of the unit are not to be reset or updated. If
the control is allowed to time out from the last position back to service (Home), the applicable statistical counters are to be reset or
updated. A manual cycling of the control can be accomplished by following the steps as outlined below.
1. While in the service mode, press the “Information” key.
2. Press the “Up” key to display the current motor position.
3. Press and hold the “Regen” key for 3 seconds until the regeneration is started. Once regeneration is active, the “Regen” key
will be ignored until the control returns to the service or “home” position.
4. The REGEN icon will flash and the motor will move the control to Backwash position.
5. Press the “Up” key to cycle to the next position and remain there until the cycle times out or the control is manually indexed.
6. Continue to press the “Up” key until the control returns to the service (Home) position. In order to step through the cycles
again, repeat at step 3.
Backwash
Press and hold the REGEN key for 5 seconds; the control should move to the
BACKWASH position.
The cycle time remaining appears at the right of the display.
Brine Rinse
Press the “Up” key; the control should move to the BRINE RINSE position.
The brine rinse time is determined by the model, tank size and salt dosage (unless dip
switch # 4 is on).
The brine rinse time is calculated value.
Fast Rinse/Refill
Press the “Up” key.
If a 4-cycle control, it will move to the FAST RINSE/REFILL position; the time is
determined by salt dosage.
Home
Press the “Up” key.
The control will return to the Home position.
Manual Cycling
28 Culligan
®
Iron-Cleer
®
Plus Water Filters
Note: If the “Down” key is pressed at any time, the control will move back to the first item in the information menu.
Pressing the “Up” key from the information menu would move the display back to the current diagnostic cycle. The “Up” key
will be ignored once the control returns back to the home position.
Note: The regeneration indicator will display “F” (flow meter), “A” (Aqua-Sensor
®
), “t”
(time clock) or “M” (manual). If the “REGEN” icon is lit, then the indicator stands for what
mode initiated regeneration. If the “REGEN” icon is NOT lit, then the indicator stands for what triggered the last regeneration.