Specifications

Controller Features
16 Culligan Medallist Series
®
Control
The Culligan Medallist Series
water softener. It can be programmed as either a time clock or Soft-Minder
®
meter model. Each
model has its own programming parameters which can be set to control the operation and regeneration of the system. These
functions are outlined in Table 1.
Table 1
Function Time Clock Soft-Minder Meter
Time of Day YES YES
Time of Regen. YES YES
Salt Dosage YES YES
Backwash Time YES YES
Brine Rinse Time YES YES
Regen. Interval / Gallons Capacity YES YES
Forced Regen. Interval NO YES*
Lock/Unlock display YES YES
* When Time Clock Backup is set to “ON”.
Circuit Board
The AccuSoft
microprocessor circuit board controls every function of the Culligan Medallist Series
®
water softener. This board
has several unique features which allows it to perform a variety of functions. Familiarization of the board is essential for a thorough
understanding of the softener.
The AccuSoft circuit board has a set of default settings that the microprocessor will reset to whenever a meter is attached or
removed from the control. Table 2 is a list of the default microprocessor settings.
It is recommended to always disconnect the power from the circuit board prior to replacing meter cable so that the programmed
settings are not lost.
Table 2
Time of Day 12:00 P.M.
Time of Regeneration 2:00 A.M.
Salt Dosage 8 lbs.
Backwash Time 10 min.
Brine Rinse 60 min.
Regeneration Interval 3 days or 870 gallons
Display Lock Out Disabled