Specifications

20 Culligan Medallist Series
®
Mount The Control Valve - 1” Control
See Figure 11 for a visual on mounting the control valve to the tank.
Assemble the o-rings, located in the parts pack, to the tank adapter.
The valve adapter o-ring sits on the rst step on the adapter. See
Figure 12.
Lubricate only the top o-ring on the tank adapter, and the outlet
manifold o-ring with silicone lubricant.
Screw the adapter into the tank until the adapter bottoms out on the
tank ange.
Align the manifold with the center opening in the valve, and press
the valve onto the adapter rmly.
Assemble the tank clamp to the control, and tighten the clamp
screw.
Flow Control and Eductor Nozzle
Listed below is the recommended eductor nozzle to be used at various
salt dosages.
Unit
Backwash
Flow
Nozzle Throat
Brine Refill
Flow
8” #1, Black* Blue* Light Brown* 0.45 gpm
Medallist 30 #2, Brown* Blue* Light Brown* 0.45 gpm
Medallist 45 #2, Brown
@ 6 lbs - Blue
Greater than
6 lbs - Beige
Light Brown 0.45 gpm
Medallist 60 #3, Green Beige Light Brown 0.8 gpm
* Standard from factory.
Refer to gure 13 for a visual on changing the eductor nozzle and the backwash
ow control.
Figure 12
Figure 13
Figure 11
Note: Do not push the top o-ring down to the flange surface on
the adapter.
Note: The larger of the two o-rings in the parts part goes
between the adapter and the valve, do not stretch the smaller
o-ring onto the top of the tank adapter.
Note: The adapter only needs to be tightened hand-tight to the
tank flange.
Note: Make sure to push the valve straight down onto the
manifold. If the valve is cocked, it may cause the o-ring to slip off
the manifold.
Note: The clamp and valve will be able to rotate on the tank
until pressure is applied. Do not try to rotate control valve if the
clamp is tightened - you may cut the o-ring.