Specifications

Settings 29
Fill the Salt Storage Container
Fill the salt storage container with water until the level reaches about 1 inch above the salt support plate. Pour
salt into the container. Fill with salt to within a few inches of the top.
Brine Valve “A” Dimension
The Culligan Medallist Series
®
unit contains a brine oat which can serve as a backup rell shutoff in the event
of a failure, such as a power outage when in the rell position. The oat level should be set based on the salt
dosage setting. Refer to gure 22.
Remove nut retaining brine valve to brine chamber.
Lift the brine valve from the brine chamber.
Find the correct “A” dimension from Appendix A, Table 5.
Set the distance from the top of the lter screen to the base of the oat accordingly. The slight difference in
height when the oat is pulled up or down is negligible.
Re-install into brine chamber and replace nut.
“A” Dimension
Figure 22