Specifications

Dip Switch Definitions
The circuit board is shipped with all DIP switches in the off position. Prior to programming the controller some DIP switches may
need to be moved to the ON position. Because each switch serves a specic purpose, please review the following information,
moving the required switches to an ON position as necessary for each controller in the system. The denitions and purpose are as
follows:
Switch # Abbreviation Denition Purpose
1 R / T Run / Test
Off - Allows controller to function in a
normal, operational mode.
On - Places controller in test mode to verify
operation of the board components &
software.
2 D / I Delayed / Immediate
Off - Regeneration will occur at Delayed
Time of Day upon a controller receiving a
valid regeneration initiation signal.
On - Regeneration shall occur immediately
upon a controller receiving a valid
regeneration initiation signal, regardless of
the time of day.
3 SO / FI Softener / Filter
Off - The unit shall be operated as a
softener.
On - The unit shall function as a lter. The
default time programmed for cycle #2 shall
be 2 minutes.
4 - / TCB
Time Clock Back-up Disabled
/ Enabled
Off - The time clock backup option is not
enabled.
On - Allows the user to enable the time
clock function of the control as a backup
regeneration initiation option. This feature
is used as a back up to a primary device
such as a ow meter.
5 E / M English / Metric
Off - The unit will function in standard
English dimensions.
On - The unit will function in standard
metric dimensions.
6 12 / 24 12 Hour Clock / 24 Hour Clock
Off - All time keeping functions shall be
based on an AM/PM basis. The PM icon
shall be lit in the display as appropriate.
On - Time keeping functions shall work on
a 24-hour clock (military time). The AM/PM
display icons will be disabled.
7 .75 “ / 1” 3/4” / 1” Control Off - 3/4” Medallist Control Valve
On - 1” Medallist Plus Control Valve
8 S / F Standard Rell / Fast Rell
Off - The 0.45 gpm rell ow control is
used to control the rell ow rate. Set in the
off position for 8” and 10” units.
On - The 0.80 gpm rell ow control is
used to control the rell ow rate. Set in the
on position for 12”
The programming menu for Medallist is outlined in the following table:
Programming
30 Culligan Medallist Series
®