Specifications

Programming 31
Setting Display Range Limits Default Comments
Time of Day 12:00 AM - 11:59 PM
(12hr)
00:00 - 23:59 (24hr)
12:00 PM
12:00
12 / 24 hour function
set with dip #6
*Time of Regeneration 12:00 AM - 11:30 PM
(12hr)
00:00 - 23:30 (24hr)
2:00 AM
02:00
- Adjust time in 30
minute increments only
-Always active UNLESS
dip #2 is on AND dip
#4 off
*Regeneration Interval Days - 01 to 99 days 03 days Only active if dip #4 is
on
*Salt Dosage 0.5 - 60 lbs (English)
0.5 - 27.5 kg (metric)
8 lbs - Not active in lter
mode
*Cycle 1 time 01 - 99 minutes 10 minutes -Always active in Flow
Meter Mode
*Cycle 2 time 01 - 99 minutes - Softener: 60 minutes
- Filter: 02 minutes
- In lter mode, default
is 2 minutes
*Batch capacity Set
Point
1 - 9,999 870 - Not active in time
clock mode.
Hidden Programming Menu
(Accessed from service mode by holding the “+” key for 5 seconds)
*Delay / Immediate
Toggle Delay or
Immediate
Delay - Locks in a regen
signal after a 3 hour or
more power outage;
regen can be set to go
immediate or delay until
the tor;
- Only accessible from
service mode, time of
day display, by pressing
and holding “+” for 5
seconds
- (not in programming
menu)
*Lock / Unlock Toggle Lock & Unlock Unlock - Lock or unlock access
to make program
changes
- Only accessible from
service mode, time of
day display, by pressing
and holding “+” for 5
seconds
- (not in programming
menu)
• To be saved in EEPROM