Specifications

32 Culligan Medallist Series
®
Make sure either inlet water supply is turned off, then supply power to the timer. The display will power up ashing “12:00 PM” and
the motor will energize and cycle the control, without stopping, the home position. This is required to ensure that the control is in
the home position.
The timer uses four buttons:
Button Description
Set-up / Enter Key (Status) Advance timer through display options
Regeneration Key (REGEN) Initiate a regeneration
Toggle Down Key (“-”) Decrease the setting
Toggle Up Key (“+”) Increase the setting
Time of Day
This setting is used to program the current time of day. When in this step the
display will rst show “tod” for two seconds.
After “tod” is displayed, “12:00 PM” will display (or the current set time if
already programmed) and the minutes will ash.
The minutes are adjusted with the “+” or “-” key until the correct
value is displayed.
Press the “Regen” key to ash the hours. Adjust with the “+” or “-”
key until the correct time is displayed.
Pressing the “Status” key will move to the next programming step. Pressing
“Regen” will move back to the minutes adjust.
Time of Regeneration
This setting is used to program the time at which a regeneration is to occur in
the delay mode, or in immediate mode with time clock backup on. The display
will rst show “tor” for two seconds.
After “tor” is shown the display will then show the default of 2:00 AM (or the
current programmed time of regeneration if already set). The time can be
adjusted in 30 minute increments by pressing the “+” or “-” keys.
Pressing the “Status” key will save the setting and move to the next
programming step.
Regeneration Interval (Time Clock Mode)
This setting is used to set the days between regeneration in time clock mode.
The display will show “REG” icon and “dAY” for two seconds and then display
the numbers to change. Adjust the value with the “+” or “-” keys.
Pressing the “Status” key will save the setting and move to the next
programming step.