Specifications

Programming 33
Regeneration Interval (Time Clock Back-up)
This setting is used to set the days between regeneration when time clock
back-up is activated in a meter mode. It is activated in meter mode if the time
clock backup DIP switch #4 is set to on. The display will show the REG icon
and tcb” for two seconds and then the number of days. Adjust the value with
the “+” or “-” keys. Pressing the “Status” key will save the setting and move to
the next programming step.
Salt Dosage
This settings used to set the salt dosage. The display will rst show “SLtP”
(SLtG for metric according to DIP switch #5 setting) for two seconds and then
display the default (or previously programmed value). Adjust the salt dosage
with the “+” or “-” keys.
Pressing the “STATUS” key will save the setting and move to the next
programming step.
Backwash Time
This setting is used to program the cycle 1 time that is usually backwash. The
time of the cycle is kept in minutes. The display will show “buu” in the display
for two seconds and then the cycle time in the right most digits. Adjust the
value with the “+” or “-” keys.
Pressing the “Status” key will save the setting and move to the next
programming step.
Brine Draw / Slow Rinse Time
This setting is used to set the time in minutes for cycle 2. This cycle is usually
brine draw / slow rinse for softeners and a settling time for lters. The display
will show “br” in the left most digits and the cycle time in the right most digits.
Adjust the value with the “+” or “-” keys. See Table 8 for suggested brine draw
/ slow rinse times.
Pressing the “Status” key will save the setting and move to the next
programming step.