Specifications

Batch Set Point
This setting is used to set the trip point for regeneration when in ow meter operation.
It will only appear if a ow meter is connected. The programmed setting displays the
actual set point to trigger regeneration. The display will show the REG icon and “CAPG”
(or “CAPL for metric) for two seconds and then display the “REG” and the setting
numbers to adjust. Adjust the value with the “+” or “-” keys.
Pressing the “Status” key will save the setting and move to the next programming step.
Immediate Regeneration Override
This setting is used to determine whether an immediate or delayed regeneration should
occur after a power outage greater than 3 hours. It applies only when dip #2 is set for
“delay”. The display will show the REG icon and “dEL” or Id” depending on the last
saved setting (default to “dEL” if EEPROM has no saved value). Toggle between “dEL”
and “Id” with the “+” or “-” key.
If set to “dEL”, then after power outage greater than 3 hours the “regen” icon will light
and the regeneration will begin when the timer reaches the next programmed time of
regeneration.
If set to “Id”, then after a power outage greater than 3 hours the regeneration will begin
as soon as the control completes the homing cycle.
Pressing the “Status” key will save the setting and go to the next Hidden Menu setting.
Screen Locking
This setting is used to lock out the user from changing most of the program menu
settings. When the “Loc” setting is saved, the only program menus that can be changed
are “tod” and “tor”. The program menu settings will appear as normal but their values
will not be able to be changed. (Note: The hidden menu can always be accessed and
settings within the hidden menu can always be changed, even if “locked”.)
The display will show “Loc” or UnL” depending on the last saved setting (default to “UnL”
if EEPROM has no saved value. Toggle between “Loc” and UnL” with the “+” or “-” keys.
Pressing the “Status” key will save the setting, exit the Hidden Menu and return to the
regular time of day Service Mode display.
34 Culligan Medallist Series
®
Blank Display
After the last programming menu is displayed (menu will vary depending on mode of
operation), pressing status will move to a blank display screen.
From the ‘blank display’, pressing the “+” key from the blank display will enter the diagnostics menu.
From the ‘blank display’, pressing the “-” key will enter the statistics menu.
From the ‘blank display’, pressing the “Status” key will exit programming mode and return to the service mode time display.
The “regen” key is ignored while in the ‘blank display’.
Hidden Programming Menu
(Accessed from the regular time of day display in service mode by holding the “+” key for 5 seconds).