Specifications

38 Culligan Medallist Series
®
The service mode allows one to view the instantaneous ow rate, the gallons remaining before the softener signals for
regeneration, the number of regenerations in the past 14 days, the total number of regenerations the control has cycled through
and the number of days since the last regeneration.
The statistical functions are reached by pressing the “Status” key until the screen blanks and then pressing the “-” key. Repetitive
presses of the “-” key will cycle through the statistics mode. Pressing the “Status” key will exit statistics and move to the time
display. The following table outlines the statistic function display, range limits and default setting:
Display Range Limits Comments
Flow Rate 0 to 999.0 Based on “K” factor setting, updated a minimum of every 6 seconds
(Only active with Flow Meter attached).
•Capacity Remaining (gal / L)
(Meter Mode)
0 - 9,999 Remaining gallons (liters) until batch capacity is reached. Update
display a minimum of every 6 seconds (Only active with Flow
Meter attached).
• Number of Regenerations
- Last 14 days
0 to 99 - Days counter is to be updated at 12:00 AM ONLY when dip #2 is
on AND dip #4 is off; Otherwise update at whatever TOR is set for
- Number of Regeneration is to be updated after a valid regeneration
is complete (cycle 3 times out automatically)
• Number of days since last
Regeneration
0 to 99 - Days counter is to be updated at 12:00 AM ONLY when dip #2 is
on AND dip #4 is off; Otherwise, update at whatever TOR is set for
- After a valid regeneration is complete (cycle 3 times out
automatically), the counter is to be reset to 0
• Number of Regenerations
- Life of the Unit
0 to 9,999 Counter is to be updated after completion of valid regeneration cycle
(cycle 3 times out automatically)
• To be saved in EEPROM before the control is powered down during a power outage.
Once the statistics menu is entered the information shown for each display is outlined below:
“Regen” key is always ignored in statistics mode;
Can enter directly into diagnostics mode by pressing the “+” key;
When returning to statistics mode directly from diagnostics mode, always display the rst statistic in the list as if statistics
mode was entered for the rst time (don’t have to remember where it left off in the list);
Can exit back to service mode by pressing the “status” key;
Automatically times out back to service mode after 10 minutes of no key press activity - EXCEPT for “ow rate” and “capacity
remaining”; when displaying “ow rate” and “capacity remaining” the control can stay in statistics mode indenitely;
Drop all leading zeros;
Flow Rate
This display will only show if the ow meter is attached to the control. The display
shall show the current ow rate of the water passing through the control. The display
will show “FLO” for two seconds and then the current ow rate passing through the
ow meter until a key is pressed.
This display shall never time out, as opposed to the rest of standard statistics
(10 minutes).
Service Check