Specifications

Specifications
Specications 5
Culligan Medallist Series
Water Conditioner With Timeclock Or Soft-Minder
®
Meter
8” Model 30 Model 45 Model 60 Model
Control Valve Type
3/4” 5-cycle Reinforced
Thermoplastic
1” 5-cycle Reinforced
Thermoplastic
1” 5-cycle Reinforced
Thermoplastic
1” 5-cycle Reinforced
Thermoplastic
Overall Conditioner Height
51 in. / 1,295 mm 49 in. / 1,245 mm 63 in. / 1,600 mm 61 in. / 1,549 mm
Media Tank Dimensions
(Dia. x Ht.)
8 x 44 in.
203 x 1,118 mm
10 x 40 in.
254 x 1,016 mm
10 x 54 in.
254 x 1,372 mm
12 x 52 in
305 x 1321 mm
Salt Storage Tank
Dimensions
(Dia. x Ht.)
16 x 43 in.
406 x 1,092 mm
18 x 43 in.
457 x 1,092 mm
18 x 43 in.
457 x 1,092 mm
18 x 43 in.
457 x 1,092 mm
Exchange Media, Type &
Quantity
Cullex
®
Media, 0.7 ft
3
Cullex Media, 1.0 ft
3
Cullex Media, 1.5 ft
3
Cullex Media, 2.0 ft
3
Underbedding, Type &
Quantity
Cullsan
®
Underbedding, 6 lb.
Cullsan Underbedding,
15 lb.
Cullsan Underbedding,
15 lb.
Cullsan Underbedding,
16 lb.
Exchange Capacity @ Salt
Dosage Per Recharge
1
17,004 gr @ 4 lb. 17,172 gr @ 4 lb. 26,770 gr @ 6 lb. 35,614 gr @ 8 lb.
22,947 gr @ 9 lb. 23,664 gr @ 8 lb. 38,830 gr @ 12 lb. 51,659 gr @ 16 lb.
24,853 gr @ 12 lb. 27,700 gr @ 12 lb. 45,493 gr @ 18 lb. 60,523 gr @ 24 lb.
Efficiency at Rated Salt
Dosage
5
4251 gr/lb
@ 4 lb. salt dosage
4293 gr/lb
@ 4 lb. salt dosage
4461 gr/lb
@ 6 lb. salt dosage
4451 gr/lb
@ 8 lb. salt dosage
Freeboard to Media
2
20.5 - 21.5 in. 13 in. 15 in. 16 in.
Freeboard to
Underbedding
3
42.0 - 42.5 in. 35 in. 48 in. 46 in.
Salt Storage Capacity
250 lb. or 375 lb. 375 lb. 375 lb. 375 lb.
Rated Service Flow @
Pressure Drop
5.9 gpm @ 12 psi 10.0 gpm @ 15 psi 9.4 gpm @ 15 psi 10.2 gpm @ 15 psi
Total Hardness, Maximum
75 gpg 75 gpg 99 gpg 99 gpg
Total Iron, Maximum
(dissolved)
5 ppm 5 ppm 5 ppm 5 ppm
Hardness to Iron Ratio,
Minimum
8 gpg to 1 ppm 8 gpg to 1 ppm 8 gpg to 1 ppm 8 gpg to 1 ppm
140 mg/L to 1 mg/L 140 mg/L to 1 mg/L 140 mg/L to 1 mg/L 140 mg/L to 1 mg/L
Operating Pressure
20 - 125 psi 20 - 125 psi 20 - 125 psi 20 - 125 psi
140 - 860 kPa 140 - 860 kPa 140 - 860 kPa 140 - 860 kPa
Operating Pressure
(Canada)
20 - 90 psi 20 - 90 psi 20 - 90 psi 20 - 90 psi
140 - 620 kPa 140 - 620 kPa 140 - 620 kPa 140 - 620 kPa
Operating Temperature
33 - 120°F 33 - 120°F 33 - 120°F 33 - 120°F
1 - 50°C 1 - 50°C 1 - 50°C 1 - 50°C
Electrical Requirements
24V/60 Hz 24V/60 Hz 24V/60 Hz 24V/60 Hz
Electrical Power
Consumption, Min./Max.
3 Watts/35 Watts 3 Watts/35 Watts 3 Watts/35 Watts 3 Watts/35 Watts
Drain Flow, Maximum
4
1.1 gpm 1.7 gpm 1.6 gpm 2.6 gpm
Recharge Time, Average
85 min. 64 min. 64 min. 52 min.
Recharge Water
Consumption
23.3 gal. 36 gal. 46 gal. 51 gal.
1 Capacities and corresponding salt dosages pertain to low hardness waters. Capacities given per recharge
2 Measured from top of media to top of inlet tting (backwashed and drained) for 8” tanks. Measured from top of media to top surface of tank
threads for 10” and 12” tanks.
3 Measured from top of underbedding to top of inlet tting for 8” tanks. Measured from top of media to top surface of tank threads for 10” and 12”
tanks.
4 Backwash at 120 psi (830 kPa)
5 Efciency rating only valid at stated salt dosage on Soft-Minder models and is efciency rated according to NSF/ANSI Standard 44