Specifications
Specifications
Specications 5
Culligan Medallist Series
™
Water Conditioner With Timeclock Or Soft-Minder
®
Meter
8” Model 30 Model 45 Model 60 Model
Control Valve Type
3/4” 5-cycle Reinforced
Thermoplastic
1” 5-cycle Reinforced
Thermoplastic
1” 5-cycle Reinforced
Thermoplastic
1” 5-cycle Reinforced
Thermoplastic
Overall Conditioner Height
51 in. / 1,295 mm 49 in. / 1,245 mm 63 in. / 1,600 mm 61 in. / 1,549 mm
Media Tank Dimensions
(Dia. x Ht.)
8 x 44 in.
203 x 1,118 mm
10 x 40 in.
254 x 1,016 mm
10 x 54 in.
254 x 1,372 mm
12 x 52 in
305 x 1321 mm
Salt Storage Tank
Dimensions
(Dia. x Ht.)
16 x 43 in.
406 x 1,092 mm
18 x 43 in.
457 x 1,092 mm
18 x 43 in.
457 x 1,092 mm
18 x 43 in.
457 x 1,092 mm
Exchange Media, Type &
Quantity
Cullex
®
Media, 0.7 ft
3
Cullex Media, 1.0 ft
3
Cullex Media, 1.5 ft
3
Cullex Media, 2.0 ft
3
Underbedding, Type &
Quantity
Cullsan
®
Underbedding, 6 lb.
Cullsan Underbedding,
15 lb.
Cullsan Underbedding,
15 lb.
Cullsan Underbedding,
16 lb.
Exchange Capacity @ Salt
Dosage Per Recharge
1
17,004 gr @ 4 lb. 17,172 gr @ 4 lb. 26,770 gr @ 6 lb. 35,614 gr @ 8 lb.
22,947 gr @ 9 lb. 23,664 gr @ 8 lb. 38,830 gr @ 12 lb. 51,659 gr @ 16 lb.
24,853 gr @ 12 lb. 27,700 gr @ 12 lb. 45,493 gr @ 18 lb. 60,523 gr @ 24 lb.
Efficiency at Rated Salt
Dosage
5
4251 gr/lb
@ 4 lb. salt dosage
4293 gr/lb
@ 4 lb. salt dosage
4461 gr/lb
@ 6 lb. salt dosage
4451 gr/lb
@ 8 lb. salt dosage
Freeboard to Media
2
20.5 - 21.5 in. 13 in. 15 in. 16 in.
Freeboard to
Underbedding
3
42.0 - 42.5 in. 35 in. 48 in. 46 in.
Salt Storage Capacity
250 lb. or 375 lb. 375 lb. 375 lb. 375 lb.
Rated Service Flow @
Pressure Drop
5.9 gpm @ 12 psi 10.0 gpm @ 15 psi 9.4 gpm @ 15 psi 10.2 gpm @ 15 psi
Total Hardness, Maximum
75 gpg 75 gpg 99 gpg 99 gpg
Total Iron, Maximum
(dissolved)
5 ppm 5 ppm 5 ppm 5 ppm
Hardness to Iron Ratio,
Minimum
8 gpg to 1 ppm 8 gpg to 1 ppm 8 gpg to 1 ppm 8 gpg to 1 ppm
140 mg/L to 1 mg/L 140 mg/L to 1 mg/L 140 mg/L to 1 mg/L 140 mg/L to 1 mg/L
Operating Pressure
20 - 125 psi 20 - 125 psi 20 - 125 psi 20 - 125 psi
140 - 860 kPa 140 - 860 kPa 140 - 860 kPa 140 - 860 kPa
Operating Pressure
(Canada)
20 - 90 psi 20 - 90 psi 20 - 90 psi 20 - 90 psi
140 - 620 kPa 140 - 620 kPa 140 - 620 kPa 140 - 620 kPa
Operating Temperature
33 - 120°F 33 - 120°F 33 - 120°F 33 - 120°F
1 - 50°C 1 - 50°C 1 - 50°C 1 - 50°C
Electrical Requirements
24V/60 Hz 24V/60 Hz 24V/60 Hz 24V/60 Hz
Electrical Power
Consumption, Min./Max.
3 Watts/35 Watts 3 Watts/35 Watts 3 Watts/35 Watts 3 Watts/35 Watts
Drain Flow, Maximum
4
1.1 gpm 1.7 gpm 1.6 gpm 2.6 gpm
Recharge Time, Average
85 min. 64 min. 64 min. 52 min.
Recharge Water
Consumption
23.3 gal. 36 gal. 46 gal. 51 gal.
1 Capacities and corresponding salt dosages pertain to low hardness waters. Capacities given per recharge
2 Measured from top of media to top of inlet tting (backwashed and drained) for 8” tanks. Measured from top of media to top surface of tank
threads for 10” and 12” tanks.
3 Measured from top of underbedding to top of inlet tting for 8” tanks. Measured from top of media to top surface of tank threads for 10” and 12”
tanks.
4 Backwash at 120 psi (830 kPa)
5 Efciency rating only valid at stated salt dosage on Soft-Minder models and is efciency rated according to NSF/ANSI Standard 44