Specifications

Preparation
6 Culligan Medallist Series
®
Component Description
The water conditioner is shipped from the factory in a minimum of three cartons. Remove all components from their cartons and
inspect them before starting installation.
Control Valve Assembly - Includes the 5-cycle regeneration control valve and the Accusoft
®
Microprocessor. A small parts pack
will contain additional installation hardware. An Owner’s Guide is included.
Media Tank - 8” and 10” media tanks are shipped lled with Cullex
®
ion exchange resin, underbedding and outlet manifold. For
12” tanks, the Cullex
®
ion exchange reclaim and underbedding are loaded at the installation site.
Salt Storage Tank Assembly - Includes salt storage container with support plate and Dubl-Safe
brine rell valve and chamber.
Bypass Valve - Includes the Cul-Flo-Valv
®
, interconnecting couplings, and the screws necessary for assembly (Bypass Valve
included with Control for Medallist Plus).
Tools and Materials
The following tools and supplies will be needed, depending on installation method.
All Installations
Safety glasses
Phillips screwdrivers, small and medium tip.
Gauge assembly (PN 00304450 or equivalent)
Silicone lubricant (PN 00471507 or equivalent) - DO NOT USE PETROLEUM-BASED LUBRICANTS
A bucket, preferably light-colored
Towels
Special Tools
Torch, solder and ux for sweat copper connections
Use only lead-free solder and ux for all sweat-solder connections, as required by state and federal codes.
Threading tools, pipe wrenches and thread sealer for threaded connections.
Saw, solvent and cement for plastic pipe connections.
Materials
Brine line, 3/8” (PN 01009819 or equivalent) for 8” and 10” tanks or 1/2” (PN 00901800 or equivalent) for 12” tanks.
Drain line, 1/2” (PN 00303082, gray, semi-exible; or PN 00-3319-46, black, semi-rigid; or equivalent)
Thread sealing tape
Pressure reducing valve (if pressure exceeds 125 psi [860 kPa], PN 00490900 or equivalent)
Pipe and ttings suited to the type of installation
Water softener salt (rock, solar or pellet salt formulated specically for water softeners)
Note: Check and comply with your state and local codes. You must follow these guidelines.
For installation in Massachusetts, Massachusetts Plumbing Code 248 CMR shall be adhered to. Consult your licensed
plumber for installation of this system. This system and its installation must comply with state and local regulations.
The use of saddle valves is not permitted.