Operating instructions

Example - Meter: Softener Model Medallist 2M
Capacity @ 9 lb. Salt Dosage: 25,100 Grains
Compensated Water Hardness: 19 Grains Per Gallon
Estimated Daily Water Usage: 300 Gallons Per Day
Treated Water Volume Set Point = — Water Usage
Softening Capacity 25,100 Grains
Divide by Compensated Hardness ÷ 19 Grains per Gallon
Result is total number of gallons 1,321 Gallons
of soft water per regeneration
Subtract daily Water Usage (needed 300 Daily Water Usage (One Day Supply)
as a reserve to ensure continuous 1,021 Gallons
soft water until regeneration occurs).
Round down to nearest ten for Treated
Water Volume Set Point 1,020 Gallon Setting
Set "CAPG" to 102
Example - Timeclock: Softener Model Medallist 2
Capacity @ 9 lb. Salt Dosage: 25,100 Grains
Compensated Water Hardness: 19 Grains Per Gallon
Estimated Daily Water Usage: 300 Gallons Per Day
Treated Water Volume Set Point = — Water Usage
Softening Capacity 25,100 Grains
Divide by Compensated Hardness ÷ 19 Grains per Gallon
Result is total number of gallons 1,321 Gallons
of soft water per regeneration
Subtract daily Water Usage (needed 300 Daily Water Usage (One Day Supply)
as a reserve to ensure continuous 1,021 Gallons
soft water until regeneration occurs).
Divide by daily water usage ÷ 300
3.4 Days
Round down to nearest day 3.0 Days
Set "CAP" to 3
Use the following worksheets to calculate and record the proper settings.
Treated Water Volume Set Point Work Sheet - Meter Models
1. Enter Softening Capacity
2. Divide by Compensation Hardness ÷
Result is Total Gallons of Soft Water Per Regeneration =
3. Subtract Daily Water Usage (Reserve
Result) =
Round down to nearest ten for Treated Water Volume Set Point Gallons