TROUBLESHOOTING GUIDE 25
13. Unit uses an A. Incorrect programming A. Refer to the 'Programming' section and
excessive amount of verify all settings.
salt or chemical B. Excessive water in storage tank B. Refer to problems 9 & 10.
14. Continuous ow to A. Internal seal pack leak. A. Replace seal pack as outlined in the
drain. 'Parts Replacement Guide' section.
B. Seal pack or brine piston jammed B. Replace the seal pack or brine piston
in position. as outlined in the 'Parts Replacement
Guide' section.
C. Power failure while unit was in C. Restore power to unit. Verify that unit is
regeneration. connected to a constant power source.
15. Salt water to service A. Inadequate Brine/Rinse setting for A. Refer to the 'Programming' section and
desired salt dosage. verify all settings.
B. Low water pressure lengthens brine B. Increase line pressure to a minimum of
draw time. 20 psi (140 kPa).
C. Too much brine in the storage tank C. Refer to problems 9 & 10.
PROBLEM CAUSE SOLUTION