Specifications

10
Step 5 – Programming Brine Draw/Slow
Rinse Time
Press the “Status” key after programming the
backwash time. The display will blink “br” for
3 seconds and then display the brine draw/slow rinse
time in minutes. Adjust the setting with the “+” or
“-” key. (35-99 minutes).
See Table 5 for suggested brine draw/slow rinse times.
Note: This option will not show if the control is set to Filter mode.
Step 6 – Programming Gallons (Liters) or Days
to Regeneration Meter Mode —
Press the “Status” key after programming the brine
draw/slow rinse time.
The display will blink “CAPG” (“CAPL”) for 3 seconds
and then display the gallons or liters set point.
Adjust the setting with the “+” or “-” key.
(10-9990 Gallons)(40-37000 Liters)
Note: The programmed value must be multiplied by 10 to obtain
the actual setting. For example, if 87 is shown in the display, the
control will regenerate after 870 gallons have passed through
the meter.
Timeclock Mode —
Press the “Status” key after programming the brine draw/slow rinse time.
The display will blink “CAP” for 3 seconds and then display the number of days between
regenerations.
Adjust the setting with the “+” or “-” key. (1-42 days)
Exiting Program Mode
From Step 6 (or step 7 if it is active) press the “Status” key.
The display will go blank.
Press the “Status” key again to exit programming.
Note: The control will exit the programming mode if no key press activity takes place within one minute.
7 i
87
OR
Programming (cont.)