HI-FLO® 52 AUTOMATIC WATER SOFTENERS SPECIFICATIONS AND OPERATING DATA MODELS Model 180 Model 300 Model 450 Model 600 Model 750 Model 900 1 Capacity , grains @ Maximum pounds @ Salt Dosage 1 Capacity , Minimum 2 Service Flow, Continuous Service Flow, 34 Peak Pipe Size, NPTI Resin Volume Media Tank, dia. x ht. Steel Fiberglass Brine Tank, dia. x ht. Ship. Wt., approx.
Hi-Flo 52 More CAD File: Soft_HF52_stl.
Hi-Flo 52 CAD File: Soft_HF52_frp.
More ENGINEER’S SPECIFICATION AUTOMATIC WATER SOFTENER HI-FLO® 52 1.0 1.1 1.2 1.2 2.0 2.1 CUSTOMER: DATE: SCOPE Provide as indicated a vertical pressure type water softener system complete with pressure vessel, softening resin, control valve, brine maker and electronic controller. The system will be of an approved design as fabricated by a manufacturer regularly engaged in the production of water treatment equipment.
More 3.2 DESIGN PARAMETERS Normal System Flow & Pressure Drop: gpm @ 15 PSI Maximum System Flow & Pressure Drop: gpm @ 25 PSI Backwash/Rinse Flow: gpm Backwash Volume: gallons nominal Daily Water Usage: gallons per day (gpd) Daily Hours of Water Demand: Operating Temperature Range: 40°–120°F Operating Pressure Range (System): 30–100 PSI Electrical Requirements: 120 Volt, 60 Hz, 1 phase (receptacle required) ”W x ”H System Dimension (L x W x H): ”L x 3.
More ¨ (Steel vessel) 4.1.4 Tank Finish – Interior Tank interior shall have near white sandblast and be coated to 8 to 10 mil DFT with an epoxy phenolic designed specifically as a high chemical resistant, non toxic, odorless protective coating. The lining shall meet the requirements of the US Federal Register, Food and Drug Regulations, Title 21, Chapter 1, Paragraph 175.300. 4.2 INTERNAL DISTRIBUTION 4.2.
More 4.4 CONTROLS A fully integrated programmable micro-processor driven electronic controller shall be provided to automatically cycle the main operating valve through the regeneration sequence. The electronic controller shall be designed and manufactured by the same manufacturer as the water treatment equipment. The controller shall sequence all steps of an automatic regeneration and automatically return the softener to a service or stand-by mode.
More ¨ (Meter Initiated, Alternating Twin Unit) An operator selected program of immediate volume initiated regeneration for alternating twin configurations shall be available. The controller shall be capable of being programmed in the field without additional interface devices.
More ¨ (Meter Initiated systems ONLY) 4.4.3 Flow Sensor(s) ¨ (1.5” Plastic Turbine Meter) A flow sensor package shall be provided consisting of an turbine-type Hall Effect; the package shall include a total of _____ flow sensors with fittings. The fitting provided shall be a 1-1/2 inch threaded Noryl housing. A 4-foot length of cable shall be provided for direct connection to the system controller. The flow sensor package provided shall be functional within the flow range of 1 to 60 gpm.
valve controls to admit the correct volume of fresh water to the brine tank in accordance with the salt dosage setting on the controls. The brine valve will include a float operated safety shut-off valve as a back up to the timed refill from the main operating valve control to prevent brine tank overflow. 4.7 4.7.1 4.7.2 4.7.3 4.7.4 ACCESSORIES (All Optional selections) ¨ Water test kits for hardness tests will be supplied. ¨ Pressure Gauges for hard water inlet and soft water outlet.