International AUTOMATIC WATER SOFTENERS SPECIFICATIONS AND OPERATING DATA Model 180, Model 300, Model 450, Model 600, Model 750, Model 900

HI-FLO
®
52
AUTOMATIC WATER SOFTENERS
SPECIFICATIONS AND OPERATING DATA
MODELS Model 180 Model 300 Model 450 Model 600 Model 750 Model 900
Capacity
1
, grains @ 180,000 300,000 450,000 600,000 750,000 900,000
Maximum pounds 90 150 225 300 375 450
@ Salt Dosage grams @ 11,664 19,440 29,160 38,879 48,599 58,320
kilograms 41 68 102 136 170 204
Capacity
1
, grains @ 120,000 200,000 300,000 400,000 500,000 600,000
Minimum pounds 36 60 90 120 150 180
@ Salt Dosage grams @ 7,776 12,960 19,440 25,920 32,400 38,880
kilograms 16 27 41 54 68 82
Service Flow,
2
gpm 67 78 90 97 95 104
Continuous m
3
/hr 15 18 20 22 22 24
Service Flow, gpm 95 108 120 125 123 125
Peak
34
m
3
/hr 22 25 27 28 28 28
Pipe Size, NPTI in 2 2 2 2 2 2
Resin Volume cu. ft. 6 10 15 20 25 30
liters 170 283 425 566 708 850
Media Tank, dia. x ht. in 20 x 54 24 x 54 30 x 54 36 x 60 36 x 60 42 x 60
Steel cm 51 x 137 61 x 137 76 x 137 91 x 152 91 x 152 107 x 152
Fiberglass in 21 x 69 24 x 72 30 x 72 36 x 72 NA NA
cm 53 x 175 61 x 183 76 x 183 91 x 183 NA NA
Brine Tank, in 24 x 48 30 x 48 30 x 48 36 x 48 42 x 48 42 x 48
dia. x ht. cm 61 x 122 76 x 122 76 x 122 91 x 122 107 x 122 107 x 122
Ship. Wt., approx. pounds 730 1050 1580 2050 2400 2750
Steel kilograms 330 480 720 940 1090 1195
Fiberglass pounds 570 860 1250 1600 NA NA
kilograms 260 390 570 730 NA NA
1 Exchange capacities based on treating water containing 10 grains per gallon of hardness (expressed as calcium carbonate), free of color, oil, turbidity and at
a continuous flow rate of approximately 50 percent of the peak flow rate. These are nominal capacities and will vary with influent water characteristics, water
temperature, and other factors.
2 Continuous flow at 15 psi (103 kPa) pressure drop.
3 Peak flow at 25 psi (172 kPa) pressure drop.
4 Operation of a softener at peak flow rate for extended periods of time may result in a slight reduction of softening capacity. This is due to premature
hardness breakthrough.
NOTE: Operational, maintenance and replacement requirements are essential for this product as advertised.
Commercial Systems
©2000 Culligan
1-800-CULLIGAN
www.culligan.com
Printed in USA Rev. 4/00
DCO 992587
SL-0075
Moore Part No.46945