Product Manual
Table Of Contents
- Table of Contents
- 1. Important Safety Instructions
- 1.1 Warning, Caution, and Note Styles Used in This Manual
- 1.2 General Information
- 1.3 General Safety Precautions
- 1.4 Generator Set Safety Code
- 1.5 Batteries Can Explode
- 1.6 Electrical Shocks and Arc Flashes Can Cause Severe Personal Injury or Death
- 1.7 Fuel and Fumes Are Flammable
- 1.8 Exhaust Gases Are Deadly
- 1.9 The Hazards of Carbon Monoxide
- 1.10 Earth Ground Connection
- 2. Introduction
- 3. Control System
- 4. Operation - PowerCommand 1.1
- 5. Maintenance
- 6. Troubleshooting
- 6.1 Engine Is Difficult to Start or Does Not Start
- 6.2 Code 143 - Engine Oil Pressure Low (Warning)
- 6.3 Code 151 - Engine Coolant Temperature High (Shutdown)
- 6.4 Code 155 - Intake Manifold Temperature High (Shutdown)
- 6.5 Code 197 - Coolant Level Low (Warning)
- 6.6 Code 415 - Engine Oil Pressure Low (Shutdown)
- 6.7 Code 421 - Engine Oil Temperature High (Warning)
- 6.8 Code 441 - Battery Voltage Low (Warning)
- 6.9 Code 488 - Intake Manifold Temperature High (Warning)
- 6.10 Code 1438 - Fail to Crank (Shutdown)
- 6.11 Code 1472 - High AC Current (Shutdown)
- 6.12 Code 5134 - Unknown Shutdown at Idle
- 7. Manufacturing Facilities
2. Introduction2-2016
13A045R242 (Issue 7) Copyright © 2016 Cummins Inc.
Icon Description
Indicates parts or tools required.
Indicates that the component is heavy (50 lb or 23 kg or more). To
reduce the possibility of personal injury, use a hoist or get assistance to
lift.
2.3 Schedule of Abbreviations
This list is not exhaustive. For example, it does not identify units of measure or
acronyms that appear only in parameters, event/fault names, or part/accessory
names.
AmpSentry, INSITE, and InPower are trademarks of Cummins Inc. PowerCommand
is a registered trademark of Cummins Inc.
ABBR. DESCRIPTION ABBR. DESCRIPTION
AC Alternating Current LED Light-emitting Diode
AMP AMP, Inc., part of Tyco
Electronics
LTS Long Term Storage
ANSI American National
Standards Institute
LVRT Low Voltage Ride Through
ASOV Automatic Shut Off Valve MFM Multifunction Monitor
ASTM American Society for
Testing and Materials
(ASTM International)
Mil Std Military Standard
ATS Automatic Transfer Switch MLD Masterless Load Demand
AVR Automatic Voltage
Regulator
NC Normally Closed
AWG American Wire Gauge NC Not Connected
CAN Controlled Area Network NFPA National Fire Protection
Agency
CB Circuit Breaker NO Normally Open
CE Conformité Européenne NWF Network Failure
CFM Cubic Feet per Minute OEM Original Equipment
Manufacturer
CGT Cummins Generator
Technologies
OOR Out of Range










