Product Manual
Table Of Contents
- Table of Contents
- 1. Important Safety Instructions
- 1.1 Warning, Caution, and Note Styles Used in This Manual
- 1.2 General Information
- 1.3 General Safety Precautions
- 1.4 Generator Set Safety Code
- 1.5 Batteries Can Explode
- 1.6 Electrical Shocks and Arc Flashes Can Cause Severe Personal Injury or Death
- 1.7 Fuel and Fumes Are Flammable
- 1.8 Exhaust Gases Are Deadly
- 1.9 The Hazards of Carbon Monoxide
- 1.10 Earth Ground Connection
- 2. Introduction
- 3. Control System
- 4. Operation - PowerCommand 1.1
- 5. Maintenance
- 6. Troubleshooting
- 6.1 Engine Is Difficult to Start or Does Not Start
- 6.2 Code 143 - Engine Oil Pressure Low (Warning)
- 6.3 Code 151 - Engine Coolant Temperature High (Shutdown)
- 6.4 Code 155 - Intake Manifold Temperature High (Shutdown)
- 6.5 Code 197 - Coolant Level Low (Warning)
- 6.6 Code 415 - Engine Oil Pressure Low (Shutdown)
- 6.7 Code 421 - Engine Oil Temperature High (Warning)
- 6.8 Code 441 - Battery Voltage Low (Warning)
- 6.9 Code 488 - Intake Manifold Temperature High (Warning)
- 6.10 Code 1438 - Fail to Crank (Shutdown)
- 6.11 Code 1472 - High AC Current (Shutdown)
- 6.12 Code 5134 - Unknown Shutdown at Idle
- 7. Manufacturing Facilities
3. Control System 2-2016
30 A045R242 (Issue 7)Copyright © 2016 Cummins Inc.
Updating Exercise Frequency
NOTICE
Not applicable without a single phase RA series transfer switch.
To update the exercise frequency and dates on the Clock/Exerciser Menu:
1. From any Information Menu, hold down the up and down arrows simultaneously
for two seconds. The Service Menu appears.
2. Access the Time Setup screen by selecting Clock Exerciser on the Genset
Service Menu.
3. Press the down key on the Time Setup screen to access the Daylight Saving
Adjust screen.
4. Select Adjust.
5. Press the down key on the Daylight Saving Adjust Start screen.
6. Select Adjust.
7. Press Exercise Schdr on the Daylight Saving Adjust End screen.
8. Press Adjust.
When updating these settings, the functions of the keys are as follows:
• The horizontal right arrow key is used to select successive blocks for editing
settings on the screen.
• Use the + or - keys to edit the following settings:
◦ Schdr Enable: Enable or Disable
◦ Exercise Schedule: Semi-Annual (every six months), Quarterly, Monthly,
Bi-Monthly (the first and third week of every month based on the time set
when the Bi-Monthly option is selected), or Weekly
◦ Exercise Schedule: Day, Hours, Minutes, AM/PM
• Press Save to save any changes. After saving, the Save button changes to the
Adjust button.