Product Manual

Table Of Contents
6. Maintenance 9-2015
After Every After Every 12 Months or 2 Years or
24 Hours 50 Hours After 250 After 500
of Run of Run Hours
2
Hours
2
Maintenance Items Time
1
Time
Check engine oil level: If low,
top up to engine specifications
level with recommended oil.
Check charge alternator: Check
visually and audibly when the
generator set is running. To
replace, contact your authorized
distributor.
Check all exhaust components
and hardware (fittings, clamps,
fasteners, etc.): Visually inspect
the exhaust system for signs of
wear or damage. Check audibly
when the generator set is
running.
Check generator set enclosure:
Visually check enclosure. Make
sure no inlets/outlets are
restricted, service access doors
are operational. To replace
damaged parts, contact your
authorized distributor.
Check operation of operator
panel: Check display (the
system will perform a control
panel test on initial activation).
Replace component if not
functioning properly.
Check operation of Emergency
Stop Button (where fitted): With
the generator set running, press
the Emergency Stop button.
Check all systems before
resetting the fault.
Replace air cleaner.
3
Check coolant lines and radiator
hoses for leaks, wear and
cracks: Visually check the
hoses. Replace worn or
damaged components.
Clean radiator core.
3
68 A051X877 (Issue 3)