Specifications

Cummins
®
, Onan
®
, the "C" logo, Performance you rely on.
TM
and Quiet Gasoline
TM
are
servicemarks, trademarks and/or registered trademarks of Cummins Inc.
Specifications are subject to change without notice
©2011 Cummins Power Generation. All Rights Reserved.
A-1441g (5/11)
Commercial generator set
Quiet Gasoline
TM
Series
QG 7000
Features and benefits
Weight, size and sound level
Integrated hydraulic pump option (pictured)
Quietest and lowest vibration generator set in Its
class
Integrated housing design
Enclosed muffler for ease of installation
Self-diagnostic capability to simplify troubleshooting
Runs two ACs with power to spare
Digital regulation for voltage stability as loads
change
2-year limited warranty, 5-year drive warranty
Weight: 290 lb (132 kg)
Size: Length 33.6 in (853 mm), width 22.2 in (563 mm),
height 16.7 in (425 mm)
Sound: 70 dB(A) at 10 ft (3 m), typical installation, full
load
Models and ratings
Model Fuel Hz
W
atts Voltage
A
mps PF Phase Circuit breaker
7 HGJAE-2132
Gasoline 60 7000 120 58.3 1.0 1 2 pole, 30 A
7 HGJAE-2556#
Gasoline 60 7000 120/240 29.2 1.0 1 2 pole, 30 A
7 HGJAE-1912
Gasoline 60 7000 120/240 29.2 1.0 1 2 pole, 30 A
7 HGJAE-6758
Gasoline 60 7000 120/240 29.2 1.0 1 2 pole, 30 A
7 HGJAE-2137
Gasoline 60 7000 120/240 16.8 1.0 3 3 pole, 18 A
6.5 HGJAE-2145
LP vapor 60 6500 120/240 27.1 1.0 1 2 pole, 30 A
6.5 HGJAE-3554
LP vapor 60 6500 120 54.0 1.0 1 2 pole, 30 A
- All 60 Hz models operate at 2880 r/min.
- Ratings apply up to 3000 ft (914 m) altitude, 85° F (29.4° C).
- Derating: Power output will decrease 3.5% for each 1000 ft (305 m) above 3000 ft (914 m), temperature derate not required for ambient**
temperatures under 120° F (49.2° C).
- Ratings are at intermittent power output. Continuous ratings are 90% of intermittent.
# Splined shaft.
** Ambient is defined as the air temperature measured at the cooling air inlet to the set.
Evaporative spec: For trailer applications required to meet Tier III Evaporative emissions of the California Air Resources board.
Effective January 1, 2011, gasoline generator sets on trailers, diesel chassis or any other non-motorized mobile apparatus must have an
EVAP generator set, approved tank, EVAP canister, hoses and fittings all meeting the CARB Tier 3 and EPA phase 3 standards and
specifications. This law applies in all 50 states.

Summary of content (4 pages)