Specifications
Cummins
®
, Onan
®
, the "C" logo, Performance you rely on.
TM
and Quiet Gasoline
TM
are
servicemarks, trademarks and/or registered trademarks of Cummins Inc.
Specifications are subject to change without notice
©2011 Cummins Power Generation. All Rights Reserved.
A-1441g (5/11)
Standard features
Engine details
Mechanical governor adjustable from service side
Cummins Onan OHV engine
Pressurized Thru Flow cooling system
4-point mounting system with coil spring vibration
isolators
Universal mounting tray with structural capability to
support the generator set in commercial mobile
applications
Integral USDA Forest Service-approved spark-arrestor
muffler
Integral control box
Instant one-touch stop switch
Electronic ignition
Self diagnostic capability
Hour meter
Battery charging - 5 A
Remote disable/continuous stop
Start and run without AC output - engine run only
Enclosed muffler provides noise reduction and ease of
installation
Sound-attenuated housing
Waterproof remote connector
Heavy-duty solenoid shift starter
Fuel filter
Spin-on, full-flow oil filter
Low oil pressure protection
Over/under speed protection
Low power factor field overcurrent protection
Digital voltage regulation
Hydraulic pump standard on some models
10 ft generator set output lead
Typical fuel consumption
Model: Cummins Onan OHV EH65V gasoline engine
Design: 4-cycle, OHV, 90-degree V-twin
Cylinders: 2
Bore: 80 mm
Stroke: 65 mm
Displacement: 39.8 in
3
(653 cm
3
)
Compression ratio: 8:1
Oil capacity: 2.0 qt (1.9 L) including filter
Power (max): At 2880 r/min: - Gasoline-fueled
models: 14.0 hp - LP-fueled models: 11.6 hp
Cooling: Centrifugal blower, generator set mounted for
high effectiveness, pressurized system, vertical flow
Cooling air volume: 60 Hz: 500 ft
3
/min (14.2 m
3
/min)
at 2880 r/min. Air flow includes engine, generator set and
control cooling air flow
Fuel system:
Replaceable dry element air cleaner
- Gasoline - sidedraft carburetor
Electronic fuel pump with positive fuel shutoff (3 psi),
maximum fuel lift 3 ft (0.9 m), Automatic choke with
vacuum pull-off
Combustion air volume: 60 Hz: 18.9 ft
3
/min (0.53
m
3
/min) at 2880 r/min
- LPG - sidedraft mixer with demand regulator
Combustion air volume: 60 Hz: 18.3 ft
3
/min (0.51
m
3
/min) at 2880 r/min
Starting system: Remote, 12 V, negative ground;
automotive type starter with steel pinion and ring gear,
automatic start disconnect, connector for remote start
cable, start-stop rocker switch mounted on set control
Ignition system: Electronic magneto type with
resistor plugs
Lubrication: Full pressure positive displacement lube
oil pump, spin-on, full-flow lube oil filter, low oil pressure
shutdown, dipstick
Cylinder crankcase: Alloy aluminum with iron
cylinder liners cast into the block, aluminum oil base
Cylinder head: Aluminum, OHV, removable
Gasoline, Gal/hr (L/hr)
No load
Half load Full load
7.0 HGJAE
0.42 (1.6) 0.73 (2.8) 1.22 (4.6)
LP vapor, Gal/hr (L/hr)
6.5 HGJAE
0.52 (1.95) 0.90 (3.4) 1.5 (5.9)
Alternator details
Design: Cummins Onan, revolving field, AC, 2-pole self-
excited, two bearing design
Insulation system and temperature rise: Meets
requirements of NEMA MG-1 and CSA C22.2, Std. 100
Motors and Generators
Cooling: Direct drive centrifugal blower, cast aluminum
housing for excellent heat transfer
Rotor: Laminated electrical steel assembly press-fitted
to shaft, balanced; heavy insulated copper wire windings;
optimized air gap for improved waveform and motor
starting; Class 200 magnet wire
Stator: Laminated electrical steel assembly, skewed for
improved waveform; Class 200 quadrature wire with 70%
more insulation over comparable generator sets
Excitation: Capped, digital voltage regulation
DC brushes: Electrographic; long life
Bearing: Double-sealed pre-lubricated ball bearings
Generator set details
Hydraulic pump
- Fixed displacement gear pump, 1.8 Gal/min at 2500 psi
- Hydraulic pump is rated with the pump idle
- When using a non-Cummins Onan pump supplied by
the customer, the hydraulic pump shaft seals must be
capable of operating in a temperature environment of
225° F to 250° F. Seal failure will result in equipment
damage
Frequency regulation
No load/Full load 5.0% Frequency regulation Constant load 1.7%
Voltage regulation