Specification Sheet
Performance you rely on.
TM
cumminsonan.com
©2015 Cummins Power Generation Inc. | A-1399p (8/15)
Specification sheet
RV generator set
Quiet Gasoline
TM
Series RV QG
4000
Features and benefits
Microprocessor control with diagnostics.
Exceptionally smooth, quiet operation.
Sealed connectors.
Full housing with enclosed muffler.
3-year limited warranty.
Lightweight, compact.
OHV engine for efficiency, no decarboning.
Weight, size and sound level
Weight:
178 lbs (80.7 kg)
Size:
Length 30.0 in (762 mm), width 19.7 in
(500.4 mm), height 14.4 in (353.1 mm)
Sound:
68
dB(A) readings at 10 ft (3 m) half load
Meets National Park Service sound level requirements
(60 dB(A) @ 50 ft) for use in national parks.
Typical installation will further reduce sound level.
Dimensions are representative of 60 Hz models.
Models and ratings
Model Fuel Packaging Hz RPM Watts Voltage Amps Phase
Circuit
breaker
4KYFR65697
Gasoline Crated 60 3600 4000 100 (1) 40.0 1 20 A, 2-pole
4KYFA26100 (37200**)
Gasoline Tubbed 60 3600 4000 120 33.3 1 30 A, 1-pole
4KYFA6747* (7858**)
Gasoline Tubbed 60 3600 4000 120 33.3 1 30 A, 1-pole
4KYFR11429
Gasoline Crated 60 3600 4000 100 (2) 40.0 1 20 A, 2-pole
3.6KYFA26120 (37230**)
LP Tubbed 60 3600 3600 120 30.0 1 30 A, 1-pole
3.3KYFR4858
LP Crated 50 3000 3300 230 (2,4) 14.3 1 17 A, 1-pole
3.6KYFR4856
Gasoline Crated 50 3000 3600 230 (2,4) 15.7 1 17 A,1-pole
(1) Isolated neutral, (2) Grounded neutral, (3) Adjustable 220-240, (4) Australia/New Zealand wire colors.
Ambient conditions for rated power output with muffler and RV enclosure, per ISO 8528-1:
- Temperature: 77° F (25° C)
- Altitude: 500 ft (152.4 m), (99 kPa dry)
Typical power output change based on ambient conditions:
- Temperature: Power output decreases 1% for every 10° F (5.5° C) increase
- Altitude: Power output decreases 3.5% for every 1000 ft (305 m) increase
Ratings represent minimums. Actual performance may be significantly higher based on installation and operating conditions.
* Evaporative spec: For trailer applications required to meet Tier III Evaporative Emissions of the California Air
Resources Board.
** Factory OEM packaging
The 60 Hz 100V and 50 Hz sets are not certified for application in North America.
Effective January 1, 2011, gasoline generator sets on trailers, diesel chassis or any other non-motorized mobile
apparatus must have an EVAP generator set, approved tank, EVAP canister, hoses and fittings all meeting the CARB
Tier 3 and EPA phase 3 standards and specifications. This law applies in all 50 states.
Operating temperature range
Low High
Gasoline
-20° F (-29° C) 120° F (49° C)
LP
0° F (-18° C) 120° F (49° C)
- Depends upon LP tank capacity, surface area and butane content of LPG.