Standard features
Engine details
2-cylinder diesel engine
Brush type alternator
Digital voltage regulation, no adjustments required
Bottom and side air inlet and outlet
Integral enclosed muffler with stationary exhaust pipe
connection point
USDA approved spark arrestor
Internal radiator
Intake silencer
Replaceable dry element air cleaner
Maintenance-free electronic governor
Fused DC circuits
Battery charging - 4 A
Hour meter
Waterproof connector for remote operation
Focalized mounting system with 3-point vibration
isolation
Over voltage, low oil pressure, over temp, over speed
and overload safeties
Bulkhead type connections for fuel and battery
Terminal block connection for AC output
Electric fuel pump
Fuel filter
Full flow oil filter
Service and maintenance from below or side service
access panel
Automatic timed glow plugs for quick easy start
Instant one-touch stop
Model: Kubota Z482
Design: 4-cycle, liquid-cooled diesel engine
Cylinders: 2, inline vertical
Bore: 2.64 in (67 mm)
Stroke: 2.68 in (68 mm)
Displacement: 29.23 in
3
(479 cm
3
)
Compression ratio: 23:1
Lube oil capacity: 2.0 qt (1.9 L)
Cooling system capacity: 3.0 qt (2.84 L)
Power (max): At 3000 rpm: 11.1 hp (8.3 kW) SAE net
intermittent
Starting system: Remote, 12 V
Average fuel consumption:
No. 2 diesel fuel, Gal/hr (L/hr)
No load
Half load Full load
5 HDKBC
0.25 (0.95) 0.39 (1.47) 0.60 (2.27)
5 HDKBB
0.20 (0.74) 0.32 (1.23) 0.54 (2.04)
A
lternato
r
details
Generator set details
Design: Cummins Onan, revolving field, AC, 2-pole
Insulation system and temperature rise: Class
H
Exciter system: Capped, digital voltage regulation
DC brushes: Electrographic; long life
Bearings: Double-sealed pre-lubricated ball bearings
Cooling: Direct drive centrifugal blower
Control
- Microprocessor control
- Integrated generator set and engine control
- User and service personnel accessible diagnostics
- Fused DC circuits
- Over voltage safety
- Hour meter
- Low oil pressure safety
- Over speed safety
- Overload safety
- Automatic timed glow plugs based on ambient
temperature
- One-touch stop
Frequency regulation
No load/Full load +/- 5% Constant load +/- 1%
Voltage regulation
No load/Full load +/- 1% Constant load +/- 2%