Specification Sheet

Performance you rely on.
TM
cumminsonan.com
©2015 Cummins Power Generation Inc. | A-1440l (8/15)
Specification sheet
Commercial
generator set
Quiet Gasoline
TM
Series QG 5500
Features and benefits
Integrated hydraulic pump option (pictured)
Quietest and lowest vibration generator set in
Its class
Integrated housing design
Enclosed muffler for ease of installation
Self-diagnostic capability to simplify
troubleshooting
Runs two ACs
Digital regulation for voltage stability as loads
change
2-year limited warranty, 5-year drive warranty
Weight, size and sound level
Weight:
288 lbs (131 kg)
Size:
Length 33.6 in (853 mm), width 22.2 in
(563 mm), height 16.7 in (425 mm)
Sound:
69 dB(A) at 10 ft (3 m), typical installation,
full load
Models and ratings
Model Fuel Packaging Hz Watts Voltage Amps PF Phase
Circuit
breaker
5.5 HGJAE-2131 (3242**)
Gasoline Tubbed 60 5500 120 45.8 1.0 1 2 pole, 30 A
5.5 HGJAE-2555#
Gasoline Crated 60 5500 120/240 22.9 1.0 1 2 pole, 30 A
5.5 HGJAE-2135 (3246**)
Gasoline Tubbed 60 5500 120/240 22.9 1.0 1 2 pole, 30 A
5.5 HGJAE-6757 (7868**)
Gasoline Tubbed 60 5500 120/240 22.9 1.0 1 2 pole, 30 A
5.5 HGJAE-2136
Gasoliner Crated 60 5500 120/240 22.9 1.0 3 3 pole, 18 A
5.5 HGJAE-2144 (3255**)
LP Vapor Tubbed 5500 120/240 22.9 1.0 1 2 pole, 30 A
- All 60 Hz models operate at 2400 r/min.
- Ratings apply up to 3000 ft (914 m) altitude, 85 °F (29.4 °C).
- Derating: Power output will decrease 3.5% for each 1000 ft (305 m) above 3000 ft (914 m), temperature derate not
required for ambient** temperatures under 120 °F (49.2 °C). Temperature: Power output decreases 1% for every 10 °F
(5.5 °C) increase.
- Ratings are at intermittent power output.
# Splined shaft.
* Ambient is defined as the air temperature measured at the cooling air inlet to the set.
Evaporative spec: For trailer applications required to meet Tier III Evaporative emissions of the California Air
Resources board.
Effective January 1, 2011, gasoline generator sets on trailers, diesel chassis or any other non-motorized mobile
apparatus must have an EVAP generator set, approved tank, EVAP canister, hoses and fittings all meeting the CARB
Tier 3 and EPA phase 3 standards and specifications. This law applies in all 50 states.
Generator weight does not include battery charger or splined shaft.
** Factory OEM packaging