Specification Sheet

Performance you rely on.
TM
cumminsonan.com
©2015 Cummins Power Generation Inc. | A-1426k (8/15)
Specification sheet
RV generator set
Quiet Gasoline
TM
Series RV QG
7000
Features and benefits
Quietest generator set in its class.
Exceptionally low vibration levels.
Integrated design with enclosed muffler for
easy installation.
Self-diagnostic capability to simplify
troubleshooting.
Runs two air conditioners with power to
spare.
Digital voltage regulation for stability as
appliance loads change.
3-year limited warranty, lifetime drive
warranty.
Gasoline or LP fueled.
Weight, size and sound level
Weight:
299 lbs (136 kg)
Size:
Length 33.6 in (853 mm), width 22.2 in
(563 mm), height 16.7 in (425 mm)
Sound:
70 dB(A) readings at 10 ft (3 m) half load
Meets National Park Service sound level requirements
(60 dB(A) @ 50 ft) for use in national parks.
Typical installation will further reduce sound level.
Models and ratings
Model Fuel Packaging Hz RPM Watts Voltage Amps Phase
Circuit
breaker
7 HGJAB-1036
Gasoline Crated 60 2880 7000 120 58.3 1
(1) 30 A, (1)
20 A HACR
7 HGJAB-900 (911**)
Gasoline Tubbed 60 2880 7000 120 58.3 1 (2) 30 A
7 HGJAB-6756* (7867**)
Gasoline Tubbed 60 2880 7000 120 58.3 1 (2) 30 A
6.5 HGJAB-1272
LP vapor Crated 60 2880 7000 120 54.2 1
(1) 30 A, (1)
20 A HACR
6.5 HGJAB-904 (915**)
LP vapor Tubbed 60 2880 7000 120 54.2 1 (2) 30 A
Ambient conditions for rated power output with muffler and RV enclosure, per ISO 8528-1:
- Temperature: 77° F (25° C)
- Altitude: 500 ft (152.4 m), (99 kPa dry)
Typical power output change based on ambient conditions:
- Temperature: Power output decreases 1% for every 10° F (5.5° C) increase
- Altitude: Power output decreases 3.5% for every 1000 ft (305 m) increase
Ratings represent minimums. Actual performance may be significantly higher based on installation and operating
conditions.
* Evaporative spec: Effective January 1, 2011, gasoline generator sets on trailers, diesel chassis or any other non-
motorized mobile apparatus must have an EVAP generator set, approved tank, EVAP canister, hoses and fittings all
meeting the CARB Tier 3 and EPA phase 3 standards and specifications. This law applies in all 50 states.
** Factory OEM packaging
Operating temperature range
Low High
Gasoline
-20° F (-29° C) 120° F (49° C)
LP
0° F (-18° C) 120° F (49° C)
- Depends upon LP tank capacity, surface area and butane content of LPG.

Summary of content (4 pages)