Specification Sheet

Performance you rely on.
TM
cumminsonan.com
©2015 Cummins Power Generation Inc. | A-1441k (8/15)
Specification sheet
Commercial
generator set
Quiet Gasoline
TM
Series QG 7000
Features and benefits
Integrated hydraulic pump option (pictured)
Quietest and lowest vibration generator set in
its class
Integrated housing design
Enclosed muffler for ease of installation
Self-diagnostic capability to simplify
troubleshooting
Runs two ACs with power to spare
Digital regulation for voltage stability as loads
change
2-year limited warranty, 5-year drive warranty
Weight, size and sound level
Weight:
299 lbs (136 kg)
Size:
Length 33.6 in (853 mm), width 22.2 in
(563 mm), height 16.7 in (425 mm)
Sound:
70 dB(A) at 10 ft (3 m), typical installation,
full load
Models and ratings
Model Fuel Packaging Hz Watts Voltage Amps PF Phase
Circuit
breaker
7 HGJAE-2132 (3243**)
Gasoline Tubbed 60 7000 120 58.3 1.0 1 2 pole, 30 A
7 HGJAE-2556#
Gasoline Crated 60 7000 120/240 29.2 1.0 1 2 pole, 30 A
7 HGJAE-1912 (2023**)
Gasoline Tubbed 60 7000 120/240 29.2 1.0 1 2 pole, 30 A
7 HGJAE-6758 (7869**)
Gasoline Tubbed 60 7000 120/240 29.2 1.0 1 2 pole, 30 A
7 HGJAE-2137
Gasoline Crated 60 7000 120/240 16.8 1.0 3 3 pole, 18 A
6.5 HGJAE-2145 (3256**)
LP vapor Tubbed 60 6500 120/240 27.1 1.0 1 2 pole, 30 A
6.5 HGJAE-3554 (4665**)
LP vapor Tubbed 60 6500 120 54.0 1.0 1 2 pole, 30 A
- All 60 Hz models operate at 2880 r/min.
- Ratings apply up to 3000 ft (914 m) altitude, 85° F (29.4° C).
- Derating: Power output will decrease 3.5% for each 1000 ft (305 m) above 3000 ft (914 m), temperature derate not
required for ambient** temperatures under 120° F (49.2° C). Temperature: Power output decreases 1% for every 10 °F
(5.5 °C) increase.
- Ratings are at intermittent power output.
#
Splined shaft.
* Ambient is defined as the air temperature measured at the cooling air inlet to the set.
**Factory OEM packaging
Evaporative spec: For trailer applications required to meet Tier III Evaporative emissions of the California Air Resources
board.
Effective January 1, 2011, gasoline generator sets on trailers, diesel chassis or any other non-motorized mobile
apparatus must have an EVAP generator set, approved tank, EVAP canister, hoses and fittings all meeting the CARB
Tier 3 and EPA phase 3 standards and specifications. This law applies in all 50 states.
Generator weight does not include battery charger or splined shaft.