Specifications

Standard Repair Times
Procedure Number and Description
Removed
From
Chassis
RABCD
Special
S
In-Chassis
Service Accessibility Codes
6
000AG TROUBLESHOOT NO OUTPUT VOLTAGE
(AVR) (GENSET)
Step 1 Includes: −−0.5 −−
Check:
Proper output lead configuration
Genset output voltage:
Voltage at line side of breaker
Voltage at load side of breaker
Voltage sense leads secure/in good condition
Wire harness condition
Rotor
Stator
000AH TROUBLESHOOT UNSTABLE VOLTAGE,
ENGINE STABLE (GENSET)
Step 1 Includes: −−0.5 −−
Check:
Proper output lead connection
Genset output voltage:
Voltage at load side of breaker
Voltage at line side of breaker
Voltage sense leads secure/in good condition
Plugs/harness connections
000AS TROUBLESHOOT BATTERY NOT
CHARGING
Step 1 Includes: −−0.5 −−
Check:
Battery connections
Battery condition
Battery charging alternator connections