Installation manual

Page 8
SYSTEM INFO Display
The SYSTEM INFO display allows access to key
information. Pressing ENTER once will display the
reason for the last automatic action. Typical displays
are shown below:
VERSION Display
The VERSION display shows the version control
number for EC-30. Should it be necessary to contact
customer service this number will help determine the
specific configuration of your EC-30.
SETUP GENSET Displays
The SETUP GENSET displays are used to select the
type of genset used with the EC-30 and to adjust the
genset hour meter.
SETUP GENSET Display
To change the GEN TYPE after initially setting
navigate to the SETUP & INFO display and press
ENTER. Now navigate to the SETUP GENSET display
and press ENTER. The GEN TYPE will be displayed.
Press SET, the display will flash. Use the UP/DOWN
key to select the GEN TYPE and press ENTER when
the appropriate type is displayed. The GEN TYPE is
stored in permanent memory and will not have to be
changed unless the EC-30 is installed on a different
type genset.
SET Gen Hour Display
If the EC-30 is installed on an existing genset check
the hour-meter on the genset and record the reading.
ENTER the SETUP & INFO menu and navigate to the
SETUP GENSET display. Press ENTER and use the
DOWN key to select the SET Gen hour’s display.
Press SET. The next display says, ENTER to unlock.
This prevents unauthorized changes to the hour-meter.
Press ENTER to continue.
The display will flash. Hold down the UP/DOWN key
and scroll until the left most digit matches the desired
value. Release the UP/DOWN key and wait four
seconds for the underline to move to the next digit to
the right and scroll to its desired value. Set each
successive digit to the right until the correct genset
hours are displayed press ENTER. The value is stored
in permanent memory and will not have to be changed
unless the EC-30 is installed on a different genset.
The hour-meter in the EC-30 and the hour meter at the
genset may differ slightly over time due to small
differences in accuracy.
SETUP AUTO Displays
The SETUP AUTO displays may be used to change
the automatic starting parameters. AUTO< is the
default value. The symbol < indicates the factory
default value.
SafeType Display
The SafeType display allows the selection of the type
of safety input that is used to prevent automatic
operation. It should be setup the very first time the unit
is turned on as described earlier. If it has not been
setup (SafeType NONE), automatic operation will not
be allowed. If the AUTO GEN key is pressed, the
display below will appear:
Use the UP/DOWN key to select the correct type of
safety input:
Ignition: Input is connected to the vehicle
ignition system (motor homes or van
conversions).
AUTO RUN
HVAC
AUTO STOP
HVAC
AUTO RUN
LOW BAT
AUTO STOP
FULL BAT
AUTO STOP
SAFETY
AUTO STOP
SHORE ON
AUTO STOP
QT START
Genset started for
HVAC run request.
Genset stopped, HVAC
run request satisfied.
Genset stopped safety
input sensed.
SAFETY=IGNITION,
BRAKE, or PARK
Genset stopped, shore
power present.
Genset stopped, battery
full.
Genset started because
battery was low.
Dis
p
la
y
Descri
tion
AUTO STOP
NO SAFETY
Genset stopped no
safety input sensed for
30 days.
SafeType
NONE
Genset stopped at start
of Quiet Time.